{{info|This failure will also probably cause the fault where drive HV DC supply voltage does not rise when powered-on. For more details, see [[Argon supply voltage troubleshooting]].}} | {{info|This failure will also probably cause the fault where drive HV DC supply voltage does not rise when powered-on. For more details, see [[Argon supply voltage troubleshooting]].}} | ||
==SimpleMotion V2 port== | ==SimpleMotion V2 port== | ||
− | + | SimpleMotion V2 port (J2 on argon) is protected by clamping diode (type NXP PESD5V0S4UD) that is identified as D19 in the adapter and Argon drive. That diode typically burns if 24VDC is miswired in the port or if faulty Ethernet/RJ45 cable is being used. Same diode exists also in the [[SimpleMotion V2 USB adapter]] and may be damaged as well. Sometimes fault propagates longer and kills also RS485 driver chip (Texas Instruments SN65176BDR) which is identified as IC4 on Argon and IC1 on SM V2 USB Adapter. | |
Typical symptom of failure is inability to connect drive through SimpleMotion bus (i.e. Granity does not connect). Sometimes D19 short circuits 5V bus to ground making devices appear completely dead. To test if the device still has life, removing D19 (and possibly IC1 or IC4) can be used to verify whether lights come on when voltage is applied to the device. | Typical symptom of failure is inability to connect drive through SimpleMotion bus (i.e. Granity does not connect). Sometimes D19 short circuits 5V bus to ground making devices appear completely dead. To test if the device still has life, removing D19 (and possibly IC1 or IC4) can be used to verify whether lights come on when voltage is applied to the device. | ||
Line 38: | Line 38: | ||
{{tip|As D19 is a protection device, drive works without it as well, so it is possible to repair the drive just by removing D19. However without the diode, rest of the electronics inside drive are vulnerable to the same error that caused D19 to burn. Operating without D19 will always terminate warranty.}} | {{tip|As D19 is a protection device, drive works without it as well, so it is possible to repair the drive just by removing D19. However without the diode, rest of the electronics inside drive are vulnerable to the same error that caused D19 to burn. Operating without D19 will always terminate warranty.}} | ||
− | |||
− |