Editing Determining Argon hardware failure
Your changes will be displayed to readers once an authorized user accepts them. (help) |
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 28: | Line 28: | ||
Typical repair procedure | Typical repair procedure | ||
− | # | + | #Is to eliminate the wiring error to prevent same mistake again |
#Remove D19 | #Remove D19 | ||
#Try drive communication (just 24V supplied and RJ45 wired straight to SMV2USB). | #Try drive communication (just 24V supplied and RJ45 wired straight to SMV2USB). | ||
Line 38: | Line 38: | ||
{{tip|As D19 is a protection device, drive works without it as well, so it is possible to repair the drive just by removing D19. However without the diode, rest of the electronics inside drive are vulnerable to the same error that caused D19 to burn. Operating without D19 will always terminate warranty.}} | {{tip|As D19 is a protection device, drive works without it as well, so it is possible to repair the drive just by removing D19. However without the diode, rest of the electronics inside drive are vulnerable to the same error that caused D19 to burn. Operating without D19 will always terminate warranty.}} | ||
− | |||
− |