Difference between revisions of "Argon user guide/Mating connectors and accessories"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(→Braking resistors) |
|||
(30 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | {{SetAUGTitle| | + | {{SetAUGTitle|mating connectors and accessories}} |
{{ArgonManualNav}}This page lists available mating connectors, accessories and spare parts for [[Argon (servo drive)]]. Most parts or equivalents are available from large number of distributors. Feel free to extend this list. | {{ArgonManualNav}}This page lists available mating connectors, accessories and spare parts for [[Argon (servo drive)]]. Most parts or equivalents are available from large number of distributors. Feel free to extend this list. | ||
− | =Connectors= | + | ==Connectors== |
− | ==J1 connector== | + | ===J1 connector=== |
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 10: | Line 10: | ||
*{{Farnell |1084673}} | *{{Farnell |1084673}} | ||
|} | |} | ||
− | ===Accessories=== | + | ====Accessories==== |
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 18: | Line 18: | ||
*{{Farnell |470028}} | *{{Farnell |470028}} | ||
|} | |} | ||
− | ==J2 | + | ===J2 connector=== |
− | Cable used for J2 should be shielded (S/FTP or FTP, ''not UTP'') type | + | ====Cable assemblies==== |
+ | Cable used for J2 should be shielded (S/FTP or FTP, ''not UTP'') type. | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 55: | Line 56: | ||
|- | |- | ||
| Shielded patch cable 10m|| Assman || A-MCSP-80050/Y-R|| {{digikey|A-MCSP-80100/Y-R}} | | Shielded patch cable 10m|| Assman || A-MCSP-80050/Y-R|| {{digikey|A-MCSP-80100/Y-R}} | ||
− | + | |} | |
+ | ====Accessories==== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Description !! Manufacturer || Part number !! Distributors and order codes | ||
+ | |- | ||
+ | | RJ45 break-out board with DIN rail fixutre (convert RJ45 to screw terminals). Helpful for wiring STO and Enable wires. || Camden boss ||CIM/RJ45 || {{farnell|2211819}} | ||
|} | |} | ||
− | ==J3 connector== | + | ===J3 connector=== |
This part is included with Argon package. | This part is included with Argon package. | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 71: | Line 78: | ||
|} | |} | ||
− | ==J4 connector== | + | ===J4 connector=== |
This part is included with Argon package. | This part is included with Argon package. | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 85: | Line 92: | ||
|} | |} | ||
− | ==J5 connector== | + | ===J5 connector=== |
[[File:Idcterminal.png|thumb|Example of DIN rail attachable IDC terminal block/breakout board.]] | [[File:Idcterminal.png|thumb|Example of DIN rail attachable IDC terminal block/breakout board.]] | ||
Mating connector type is 0.1" pitch 26 pin IDC ribbon cable socket, see [[Media:Idc_connector_data.pdf|example (pdf)]]. | Mating connector type is 0.1" pitch 26 pin IDC ribbon cable socket, see [[Media:Idc_connector_data.pdf|example (pdf)]]. | ||
Line 98: | Line 105: | ||
*{{Farnell |1099240}} | *{{Farnell |1099240}} | ||
|} | |} | ||
− | ===Accessories=== | + | ====Accessories==== |
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 108: | Line 115: | ||
[[Category:Argon user guide]] | [[Category:Argon user guide]] | ||
− | =Heat sinks & cooling= | + | =Heat sinks & cooling & high power application= |
{| class="wikitable" | {| class="wikitable" | ||
Line 114: | Line 121: | ||
! Description !! Manufacturer || Part number !! Distributors and order codes | ! Description !! Manufacturer || Part number !! Distributors and order codes | ||
|- | |- | ||
− | | Half brick heatsink. Up to 4 pcs of standard half brick heat sinks can be fitted to drive to improve cooling and increase maximum power output. | + | | Half brick heatsink. Up to 4 pcs of standard half brick heat sinks can be fitted to a drive to improve cooling and increase maximum power output. Install with thermal grease. Note: M3 mounting screws must not reach through the 5 mm thick heat sink of the drive! || Wakefield || 518-95AB || |
− | *{{Digikey | | + | *{{Digikey |345-1055-ND}} |
+ | |- | ||
+ | | Fuse, anti-surge, 6.3A. A replacement for original fuse in the drive. See [[replacing Argon fuse]]. || SCHURTER || 0001.2512 || {{Farnell|1360860}} | ||
+ | |- | ||
+ | | Fuse, anti-surge, 10A. A higher power alternative fuse. See [[replacing Argon fuse]]. || SCHURTER || 0001.2514 || {{Farnell|1360862}} | ||
+ | |- | ||
+ | | Fuse, anti-surge, 16A. A higher power alternative fuse. See [[replacing Argon fuse]]. || SCHURTER || 0034.3129 || {{Farnell|1360824}} | ||
+ | |||
+ | |} | ||
+ | |||
+ | ==[[Electromagnetic interference]] filtering== | ||
+ | {{Tip|Multiple drives may be connected behind one power line filter as long as total current consumption doesn't exceed filter rating}} | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Description !! Manufacturer || Part number !! Distributors and order codes | ||
+ | |- | ||
+ | | [[EMI suppression cores|EMI suppression core]] for low frequency band || Laird ||LFB159079-000||{{digikey|240-2281-ND}} | ||
+ | |- | ||
+ | | [[EMI suppression cores|EMI suppression core]] for medium frequency band || Laird ||28B0616-000||{{digikey|240-2306-ND}} | ||
+ | |- | ||
+ | |[[Power line filter]] for up to 12A AC input current, FN2090 series - low cost||Schaffner||FN2090-12-06||{{digikey|817-1332-ND}} | ||
+ | |- | ||
+ | |[[Power line filter]] for up to 16A AC input current, FN241x series - high performance||Schaffner||FN2412-16-44||{{digikey|817-1358-ND}} | ||
+ | |- | ||
+ | |[[Power line filter]] for up to 12A AC input current, FN350 series - optimal for single phase motor drives||Schaffner||FN350-12-29||{{digikey|817-1130-ND}} | ||
+ | |- | ||
+ | |[[Power line filter]] for up to 20A AC input current, FN350 series - optimal for single phase motor drives||Schaffner||FN350-20-29||{{digikey|817-1131-ND}} | ||
+ | |} | ||
+ | |||
+ | ==[[Argon user guide/Braking resistor|Braking resistors]]== | ||
+ | {{tip|One resistor in a multiaxis system may be sufficient if drives are [[Argon_user_guide/J4_connector_wiring|wired to share the HV DC bus between them]]}} | ||
+ | {{tip|In most installations braking resistor is not needed at all. Resistor is needed in cases where fast moving motor with high inertial load is stopped rapidly causing conversion of the kinetic energy into electric current which needs to be dissipated by a resistor. Experimenting without resistor is safe as drive's overvoltage protection will prevent any damage occurring. If drive faults to overvoltage fault during deceleration, then try adjusting {{param|FOV}} to higher value or add a braking resistor.}} | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Description !! Manufacturer || Part number !! Distributors and order codes | ||
+ | |- | ||
+ | |82 ohm 250W braking resistor for 220-240VAC installation || Tyco || Tyco HSC 250 82R || | ||
+ | *{{farnell|1619350}} | ||
+ | |- | ||
+ | |47 ohm 250W braking resistor for 110-120VAC installation || Tyco || Tyco HSC 250 47RJ ||{{farnell|1619349}} | ||
+ | |- | ||
+ | |100 ohm 150W braking resistor for 220-240VAC installation || TE Connectivity || 1630012-1 || | ||
+ | *[[Granite Devices web shop|GD web shop]] | ||
+ | *{{digikey|A102370-ND}} | ||
+ | |- | ||
+ | |100 ohm 150W braking resistor for 220-240VAC installation || Arcol || HS150100RJ || | ||
+ | *{{farnell|2504896}} | ||
|} | |} |
Latest revision as of 15:45, 24 November 2015
This page lists available mating connectors, accessories and spare parts for Argon (servo drive). Most parts or equivalents are available from large number of distributors. Feel free to extend this list.Connectors[edit | edit source]
J1 connector[edit | edit source]
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
PLUG, D, SOLDER, 15WAY | MULTICOMP | 5501-15PA-02-F1 |
|
Accessories[edit | edit source]
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
D-SUB BACKSHELL, 15WAY | MH CONNECTORS | DPPK15-GREY-K |
|
J2 connector[edit | edit source]
Cable assemblies[edit | edit source]
Cable used for J2 should be shielded (S/FTP or FTP, not UTP) type.
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
Premium patch cable 0.5m | VIDEK | 3962-0.5 | Farnell 1525999 |
Premium patch cable 1m | VIDEK | 3962-1 | |
Premium patch cable 2m | VIDEK | 3962-2 | Farnell 1525753 |
Premium patch cable 5m | VIDEK | 3962-5 | Farnell 1525755 |
Premium patch cable 10m | VIDEK | 3962-10 | |
Shielded patch cable 0.5m | VIDEK | 2992-0.5 | Farnell 1517504 |
Shielded patch cable 1m | VIDEK | 2992-1 | |
Shielded Patch cable 2m | VIDEK | 2992-2 | Farnell 1517506 |
Shielded patch cable 5m | VIDEK | 2992-5 | Farnell 1517509 |
Shielded patch cable 10m | VIDEK | 2992-10 | |
Shielded patch cable 0.5m | Assman | A-MCSP-80005/B-R | Digikey A-MCSP-80005/B-R |
Shielded patch cable 1m | Assman | A-MCSP-80005/Y-R | Digikey A-MCSP-80010/Y-R |
Shielded patch cable 2m | Assman | A-MCSP-80020/Y-R | Digikey A-MCSP-80020/Y-R |
Shielded patch cable 3m | Assman | A-MCSP-80050/Y-R | Digikey A-MCSP-80030/Y-R |
Shielded patch cable 5m | Assman | A-MCSP-80050/Y-R | Digikey A-MCSP-80050/Y-R |
Shielded patch cable 10m | Assman | A-MCSP-80050/Y-R | Digikey A-MCSP-80100/Y-R |
Accessories[edit | edit source]
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
RJ45 break-out board with DIN rail fixutre (convert RJ45 to screw terminals). Helpful for wiring STO and Enable wires. | Camden boss | CIM/RJ45 | Farnell 2211819 |
J3 connector[edit | edit source]
This part is included with Argon package.
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
3 pole 0.2" pitch terminal | On Shore Technology Inc | OSTTJ035153 |
J4 connector[edit | edit source]
This part is included with Argon package.
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
10 pole 0.2" pitch terminal | On Shore Technology Inc | OSTTJ105153 |
|
J5 connector[edit | edit source]
Mating connector type is 0.1" pitch 26 pin IDC ribbon cable socket, see example (pdf).
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
SOCKET, IDC, 2.54MM, 26WAY | AMPHENOL | T812126A100CEU |
|
SOCKET, IDC, WITH S/RELIEF, 26WAY | MULTICOMP | MC6FD026-30P1 |
|
Accessories[edit | edit source]
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
IDC terminal block, 26WAY | Camden boss | CIM/202426W-IDCS |
|
Heat sinks & cooling & high power application[edit | edit source]
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
Half brick heatsink. Up to 4 pcs of standard half brick heat sinks can be fitted to a drive to improve cooling and increase maximum power output. Install with thermal grease. Note: M3 mounting screws must not reach through the 5 mm thick heat sink of the drive! | Wakefield | 518-95AB | |
Fuse, anti-surge, 6.3A. A replacement for original fuse in the drive. See replacing Argon fuse. | SCHURTER | 0001.2512 | Farnell 1360860 |
Fuse, anti-surge, 10A. A higher power alternative fuse. See replacing Argon fuse. | SCHURTER | 0001.2514 | Farnell 1360862 |
Fuse, anti-surge, 16A. A higher power alternative fuse. See replacing Argon fuse. | SCHURTER | 0034.3129 | Farnell 1360824 |
Electromagnetic interference filtering[edit | edit source]
Multiple drives may be connected behind one power line filter as long as total current consumption doesn't exceed filter rating |
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
EMI suppression core for low frequency band | Laird | LFB159079-000 | Digikey 240-2281-ND |
EMI suppression core for medium frequency band | Laird | 28B0616-000 | Digikey 240-2306-ND |
Power line filter for up to 12A AC input current, FN2090 series - low cost | Schaffner | FN2090-12-06 | Digikey 817-1332-ND |
Power line filter for up to 16A AC input current, FN241x series - high performance | Schaffner | FN2412-16-44 | Digikey 817-1358-ND |
Power line filter for up to 12A AC input current, FN350 series - optimal for single phase motor drives | Schaffner | FN350-12-29 | Digikey 817-1130-ND |
Power line filter for up to 20A AC input current, FN350 series - optimal for single phase motor drives | Schaffner | FN350-20-29 | Digikey 817-1131-ND |
Braking resistors[edit | edit source]
One resistor in a multiaxis system may be sufficient if drives are wired to share the HV DC bus between them |
In most installations braking resistor is not needed at all. Resistor is needed in cases where fast moving motor with high inertial load is stopped rapidly causing conversion of the kinetic energy into electric current which needs to be dissipated by a resistor. Experimenting without resistor is safe as drive's overvoltage protection will prevent any damage occurring. If drive faults to overvoltage fault during deceleration, then try adjusting Over voltage fault thresholdFOV to higher value or add a braking resistor. |
Description | Manufacturer | Part number | Distributors and order codes |
---|---|---|---|
82 ohm 250W braking resistor for 220-240VAC installation | Tyco | Tyco HSC 250 82R |
|
47 ohm 250W braking resistor for 110-120VAC installation | Tyco | Tyco HSC 250 47RJ | Farnell 1619349 |
100 ohm 150W braking resistor for 220-240VAC installation | TE Connectivity | 1630012-1 | |
100 ohm 150W braking resistor for 220-240VAC installation | Arcol | HS150100RJ |
|