Difference between revisions of "Argon user guide/Motor compatibility"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
Line 6: Line 6:
 
*Permanent magnet AC  
 
*Permanent magnet AC  
  
Servomotors must be equipped with an compatible [[Feedback devices]]
+
Servomotors must be equipped with an compatible [[Feedback devices]]. If motor is equipped with '''encoder''', following types are compatible:
 +
*Encoder voltage 5V
 +
*Outputs single ended or differential
 
*2 channel encoder is enough for all motor types
 
*2 channel encoder is enough for all motor types
 +
*Suitable encoder resolutions are from about 100 PPR to 131070 PPR (pulses or lines per revolution)
 
*Index channel is not required but is supported for precise homing
 
*Index channel is not required but is supported for precise homing
 
*Hall or commutation sensors are not required but are supported for AC/BLDC motors
 
*Hall or commutation sensors are not required but are supported for AC/BLDC motors
*Suitable encoder resolutions are from about 100 PPR to 131070 PPR (pulses or lines per revolution)
 
  
Motor '''voltages''' and '''currents''' can introduce some limitations to motor output speed and torque but does not cause unsuitability.
+
Motor '''voltages''' and '''currents''' can introduce some limitations to motor output speed and torque but will not cause unsuitability.
 
*'''Motor voltage''' is the limiting factor for maximum speed. For example, if you have a 200 VDC brushed DC servo motor and run it at 115 VAC using Argon, then you can expect to get a speed of 115*1.41*88%*/200V = 71% of motor's rated speed. 88% comes from Argon's effective voltage swing at power outputs (see [[Argon specifications]]).  
 
*'''Motor voltage''' is the limiting factor for maximum speed. For example, if you have a 200 VDC brushed DC servo motor and run it at 115 VAC using Argon, then you can expect to get a speed of 115*1.41*88%*/200V = 71% of motor's rated speed. 88% comes from Argon's effective voltage swing at power outputs (see [[Argon specifications]]).  
 
*'''Motor current''' is the limiting factor for maximum torque. For example, if you have motor rated for 20A DC and drive's maximum output is 10A DC, then you get 50% of the rated torque.
 
*'''Motor current''' is the limiting factor for maximum torque. For example, if you have motor rated for 20A DC and drive's maximum output is 10A DC, then you get 50% of the rated torque.
  
Argon has [[High dynamic range torque control|high dynamic range torque control]] which makes it suitable also for very small motors, such as ones with rated current around 500 mA.  
+
Argon has [[High dynamic range torque control|high dynamic range torque control]] which makes it suitable also for very small motors, such as ones with rated current around 300 mA.  
 
[[category:Argon]]
 
[[category:Argon]]
 
[[category:Setup guides]]
 
[[category:Setup guides]]

Revision as of 18:27, 16 June 2013

This is a short guide for determining whether or not a motor is suitable for Argon.

Motor type must be one of the following (rotary or linear):

  • Permanent magnet brushed DC
  • Permanent magnet brushless DC (BLDC)
  • Permanent magnet AC

Servomotors must be equipped with an compatible Feedback devices. If motor is equipped with encoder, following types are compatible:

  • Encoder voltage 5V
  • Outputs single ended or differential
  • 2 channel encoder is enough for all motor types
  • Suitable encoder resolutions are from about 100 PPR to 131070 PPR (pulses or lines per revolution)
  • Index channel is not required but is supported for precise homing
  • Hall or commutation sensors are not required but are supported for AC/BLDC motors

Motor voltages and currents can introduce some limitations to motor output speed and torque but will not cause unsuitability.

  • Motor voltage is the limiting factor for maximum speed. For example, if you have a 200 VDC brushed DC servo motor and run it at 115 VAC using Argon, then you can expect to get a speed of 115*1.41*88%*/200V = 71% of motor's rated speed. 88% comes from Argon's effective voltage swing at power outputs (see Argon specifications).
  • Motor current is the limiting factor for maximum torque. For example, if you have motor rated for 20A DC and drive's maximum output is 10A DC, then you get 50% of the rated torque.

Argon has high dynamic range torque control which makes it suitable also for very small motors, such as ones with rated current around 300 mA.