− | Connecting a protective earth to Argon drive is the most crucial single connection to be made | + | Connecting a protective earth to Argon drive is the most crucial single connection to be made: |
*'''Earthing through the J4 PE terminal''' (always required) | *'''Earthing through the J4 PE terminal''' (always required) | ||
*'''Earthing the heat sink''' (always required) | *'''Earthing the heat sink''' (always required) | ||
Line 7: | Line 7: | ||
==Earthing through the J4 PE terminal== | ==Earthing through the J4 PE terminal== | ||
This is a mandatory connection. Follow the [[Argon user guide/Wiring|Argon wiring instructions]]. | This is a mandatory connection. Follow the [[Argon user guide/Wiring|Argon wiring instructions]]. | ||
− | ==Earthing the | + | ==Earthing the heatsink== |
− | [[File:ArgonEarthing1.png|450px|thumb|Earthing points of the | + | [[File:ArgonEarthing1.png|450px|thumb|Earthing points of the heatsink]][[File:ArgonEarthing2.png|450px|thumb|Proper earthing wire installation with toothed locking washers ensure an electrical contact through surface coatings.]]Attaching protective earth wire to the heatsink and case is mandatory in addition to the PE connection in J4 terminal. |
Parts needed: | Parts needed: |
Revision as of 11:49, 5 March 2020
Connecting a protective earth to Argon drive is the most crucial single connection to be made:
- Earthing through the J4 PE terminal (always required)
- Earthing the heat sink (always required)
- Earthing the device case (always required)
Supplying power to the drive without proper earthing will allow leakage current to raise voltage potential of the device case to hazardous levels. Also ELV circuits (the other ports than J4) may become hazardous without earthing. |
Earthing through the J4 PE terminal
This is a mandatory connection. Follow the Argon wiring instructions.
Earthing the heatsink
Attaching protective earth wire to the heatsink and case is mandatory in addition to the PE connection in J4 terminal.Parts needed:
- 1pcs wire ring terminal with 4-5.5 mm hole with at least 20 Ampere capable earthing conductor
- 2pcs M4 serrated/toothed lock washers
- 1pcs M4 screw, 6-8 mm thread length
Verifying connection
After wiring, verify electrical connection by using a resistance meter between the case PE wire and J4 PE terminal while J4 PE wire is not connected.