Granity user guide/Connect
This dialog serves following purposes:
- Connecting and disconnecting to a drive
- Loading and saving settings
- Clear drive fault state
- Enable or disable motor control
- Restart drive
- Upgrade firmware of the drive
Contents
Connecting
Preparations
Before connecting drive to Granity, read through Argon setup guide.
Minimum requirements for connection:
- Argon (servo drive)
- 24VDC regulated power supply
- SimpleMotion V2 compatible communication interface device (such as SimpleMotion V2 USB adapter)
- Drive address DIP switches configured to give an unique address for drive
Establishing connection
- Connect PE of J4 connector to protective earth. After that wire 24 VDC power supply to Argon's J3 connector, however do not power up yet.
- Set Argon DIP switches to give an bus address to the device.
- Connect Argon J2.1 connector to SimpleMotion V2 USB adapter with a straight Ethernet cable and plug USB adapter to computer.
- Power up the 24 VDC power. Some leds should start blinking at the drive (specifily LD3 and/or LD4).
- Launch Granity software and:
- Go to Connect tab
- Ensure that SM V2 USB adapter is selected from drowdown list called Communication interface device
- Click Connect to drive
- Once list of connected drives pop up, select the one you connected and click Open
Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step.
Enable or disable motor control
Enable/disable feature sets drive in active (enabled) or inactive (disabled) state. In enabled state drive performs motor control (such as positioning) and in disabled states drive lets motor free-wheel (torque off) or brakes motor.
- Disabling drive
- To disable drive, click Disable drive button or Esc key from anywhere in the software
- Alternatively set logic 0 to Enable drive physical input
- Enabling drive
- To enable drive, click Enable drive buttton
- In order to enable drive, logic 1 must be at drive physical Enable drive input
- Verifying current enable/disable status
- To verify current state of drive, view device status registers.
disabling drive by software is not reliable enough for emergenecy stopping. Always have hard-wired method available for emergency situations (safe toreque off switch or cut all power) |
before clicking enable, ensure that no danger is caused by unexpected motor behavior (such as servo instability or runaway). |
Loading and saving settings
Clearing drive faults
Upgradind drive firmware
Troubleshooting
- Check if [Argon LED status indicators] are indicating an error
- Ensure that each device in the bus has unique address selected from DIP switches
- Ensure correct interface device has been selected
- Ensure that bus termination DIP setting has been turned on only on the last drive in the bus
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.