Argon firmware 2.0 public beta

From Granite Devices Knowledge Wiki
Revision as of 19:54, 28 August 2015 by Tero K (Talk | contribs) (Text replacement - "\[\[([A-Z]{2,3})\]\]" to "{{param|$1}}")


Jump to: navigation, search

Argon servo drive firmware version 2.0 public beta is available for evaluation.

The changes between 1.4.0 and 2.0.0-beta-1 are:

  • New features:
    • Added Position feed-forward gain parameter Position feed-forward gainPFF - helps to reduce overshoot in position control mode. In previous firmware, this value was fixed to 100%.
    • Simulated encoder output from internal EXT connector (6 pin header) - useful with resolver systems where external controller needs encoder count
    • Homing with index pulse search is now possible with resolver feedback device (simulated index pulse at certain resolver angle(s))
    • Added support for direction input signal in PWM and Analog setpoint modes
    • Identifies the reason why torque of motor is being limited (such as user limit or supply voltage limit). Shown in Granity Testing tab.
    • SimpleMotion V2 protocol updated to the latest version, new features:
      • added support for watchdog (stop drive if valid SM commands not arriving within predefined time period)
      • calculation of setpoint commands via SM bus renewed (drive setpoint is a sum of phyiscal setpoint (step/dir, pwm, analog etc) and the setpoint from SM host (instant and buffered commands). If SM host sets absolute setpoint, then phyiscal counter (incremental types onle) are reset to zero.)
      • in buffered command execution, now only writing to setpoint commands consume user defined time and all other commands are executed as fast as possible (i.e. now possible to modify parameters on the fly while buffered motion is running)
  • Improvements:
    • Increased continuous current output limit from 11A to 12.5A and peak current limit from 16A to 18A
    • Increased maximum overvoltage level from 382 VDC to 388 VDC
    • Support high encoder resolution encoder (up to 4 000 000 PPR, previously was 65 535 PPR). This makes possible to add SinCos encoder support in the next update.
    • Added new torque bandwidth limit choices: 4700 Hz and Unlimited
    • Phasing a.k.a. phase search algorithm improvements
      • Increased motor swing angle span to allow successful phasing in the case where motor motion is blocked in one direction
      • Increased speed
      • Use more conservative current during phasing to prevent motor heating
      • Earlier timeout if phasing is not going to succeed
    • Improve fault tolerance with Resolver feedback device
    • Improve effectiveness of regenerative resistor
    • Added compatibility for Granity 1.8.0 and later
  • Fixes:
    • Increased internal fixed overvoltage protection threshold to avoid unnecessary overvoltage faults
    • Operation of offset compensation when using Analog input with direction signal

The changes between 2.0.0-beta-1 and 2.0.0-beta-3 are:

  • Enhanced AC power soft-start circuity control

Downloads

Racing simulator build

This file is for custom firmware community:

Giving feedback

After trying the new firmware and Granity, please give us feedback by writing to tero.k (at) granitedevices.fi. Set email subject to ARGON 2.0 BETA so the feedback messages are easier to identify.

We greatly appreciate if you write us even when everything worked correctly.


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.