Editing Argon supply voltage troubleshooting
Your changes will be displayed to readers once an authorized user accepts them. (help) |
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 2: | Line 2: | ||
*[[Safe torque off|STO1]] input is not powered by 24 VDC | *[[Safe torque off|STO1]] input is not powered by 24 VDC | ||
*Drive's internal fuse has blown. To check this [[Argon user guide/Power supply safe discharging|safely discharge drive]], remove cover, remove fuse and measure fuse resistance. If high current & power is demanded from the drive, then a higher amperage fuse may be installed in the place of original. Maximum fuse size is 16A slow blow and the factory default is between 6.3-8 A slow blow. | *Drive's internal fuse has blown. To check this [[Argon user guide/Power supply safe discharging|safely discharge drive]], remove cover, remove fuse and measure fuse resistance. If high current & power is demanded from the drive, then a higher amperage fuse may be installed in the place of original. Maximum fuse size is 16A slow blow and the factory default is between 6.3-8 A slow blow. | ||
− | + | ||
==Drive internal AC circuity== | ==Drive internal AC circuity== | ||
[[File:Argon ac input.png|800px]] | [[File:Argon ac input.png|800px]] | ||
Line 34: | Line 34: | ||
Measuring condition of B3 is possible with multimeter's diode check function. Check all four diodes from the test points marked in the image. Multimeter red lead goes to anode and black to cathode. All diodes should give reading of 0.4 to 0.5 Volts. | Measuring condition of B3 is possible with multimeter's diode check function. Check all four diodes from the test points marked in the image. Multimeter red lead goes to anode and black to cathode. All diodes should give reading of 0.4 to 0.5 Volts. | ||