If there's problem getting rid of permanent under voltage fault in Argon, it may be caused by following reasons:

  • STO1 input is not powered by 24 VDC
  • Drive's internal fuse has blown. To check this safely discharge drive, remove cover, remove fuse and measure fuse resistance. If high current & power is demanded from the drive, then a higher amperage fuse may be installed in the place of original. Maximum fuse size is 16A slow blow and the factory default is between 6.3-8 A slow blow.

Drive internal AC circuity

Argon ac input.png

Inrush current limiter is based on a resistor which is bypassed by a GraniteCore controlled relay after HV DC supply has risen near nominal levels.

Verifying internal HV DC bus voltage can be done by reading the voltage value from Granity Testing tab or by measuring DC voltage between VP and VN terminals.


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.