Revision as of 21:44, 29 May 2013

High priority faults

Fault reason !! LED sequence LED sequence as text
Hardware 3SLLS.gif SLLS
Program or memory 3SLSL.gif SLSL
Internal comm error (unable to establish comm) 3SLSS.gif SLSS
Internal comm error (in middle of operation) 3SSLL.gif SSLL
SimpleMotion communication 3LSSS.gif LSSS
Other/unknown 3LLSL.gif LLSL

Faults causing fault stop state

Fault reason LED sequence LED sequence as text
Hardware 3LLSS.gif LLSS
Progral or memory 3LSLL.gif LSLL
Internal comm error (CRC) 3LSL.gif LSL
Initialization 3LSS.gif LSS
Over current 3SLL.gif SLL
Over temperature 3LSLS.gif LSLS
Over voltage 3SLS.gif SLS
Following error 3LS.gif LS
Under voltage 3SL.gif SL
Motion blocked or motor runaway 3SLL.gif SSL
Reference range exceeded 3LSSL.gif LSSL
Other/unknown 3SSSL.gif SSSL

Motor control states

Status LED sequence LED sequence as text Motor output powered
Permanent stop (need device reset) 4LLS.gif LLS No
Fault stop (observe LD3 for reason) 4OFF.gif Off Depends on fault
Follow error recovery motion 4LS.gif LS Yes
Initializing 4SL.gif SL Yes
Homing 4LSS.gif LSS Yes
Run 4ON.gif On yes