Editing Argon user guide/Wiring
Your changes will be displayed to readers once an authorized user accepts them. (help) |
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 78: | Line 78: | ||
===Connecting multiple drives=== | ===Connecting multiple drives=== | ||
Note this drawing does not include wiring to motor (J4), motor brake (J3), feedback device (J1), controller (J5) and AC power input circuity. | Note this drawing does not include wiring to motor (J4), motor brake (J3), feedback device (J1), controller (J5) and AC power input circuity. | ||
− | {{caution|Using HV DC bus sharing via VP and VN terminals or supplying external DC voltage to them, renders the [[safe torque off]] '''STO1''' input unusable because STO1 is based on by cutting the AC supply. In order to preserve STO1 functionality with DC bus sharing, the STO1 signal must be fed simultaneously to all DC bus sharing drives. If an external DC supply is used (no AC input to L & N), then STO1 will not operate | + | {{caution|Using HV DC bus sharing via VP and VN terminals or supplying external DC voltage to them, renders the [[safe torque off]] '''STO1''' input unusable because STO1 is based on by cutting the AC supply. In order to preserve STO1 functionality with DC bus sharing, the STO1 signal must be fed simultaneously to all DC bus sharing drives. If an external DC supply is used (no AC input to L & N), then STO1 will not operate.}} |
[[File:Argon_wiring_multiple.png|800px]] | [[File:Argon_wiring_multiple.png|800px]] | ||
===Wiring of single drive=== | ===Wiring of single drive=== | ||
[[File:Argonwiringoverview.png|800px]] | [[File:Argonwiringoverview.png|800px]] | ||
− | |||
− |