This dialog serves following purposes:
+
{{SetGranityTabPageTitle|Connect}}[[File:granityconnect.png|thumb]]
 +
This tab serves following purposes:
 
* Connecting and disconnecting to a drive
 
* Connecting and disconnecting to a drive
 
* Loading and saving settings
 
* Loading and saving settings
Line 11: Line 12:
  
 
Minimum requirements for connection:
 
Minimum requirements for connection:
* [[Argon (servo drive)]]  
+
* [[Argon]] or [[IONI]] motor drives
 
* 24VDC regulated power supply
 
* 24VDC regulated power supply
 
* [[SimpleMotion V2 compatible communication interface device]] (such as [[SimpleMotion V2 USB adapter]])
 
* [[SimpleMotion V2 compatible communication interface device]] (such as [[SimpleMotion V2 USB adapter]])
* Drive address DIP switches configured to give an unique address for drive
+
* [[Setting device bus address|Drive address configured]] to give an unique address for drive
  
 
===Establishing connection===
 
===Establishing connection===
 +
====Argon====
 
# Connect PE of [[Argon_wiring#J3_24V_power_and_motor_brake_port|J4 connector]] to protective earth. After that wire 24 VDC power supply to Argon's [[Argon_wiring#J3_24V_power_and_motor_brake_port|J3 connector]], however do not power up yet.
 
# Connect PE of [[Argon_wiring#J3_24V_power_and_motor_brake_port|J4 connector]] to protective earth. After that wire 24 VDC power supply to Argon's [[Argon_wiring#J3_24V_power_and_motor_brake_port|J3 connector]], however do not power up yet.
# Set Argon DIP switches to give an bus address to the device.
+
# [[Setting device bus address|Set drive address]] to give an bus address to the device.
# Connect Argon J2.1 connector to [[SimpleMotion V2 USB adapter]] with a straight Ethernet cable and plug USB adapter to computer.
+
# Connect Argon J2 (any of two ports) connector to [[SimpleMotion V2 USB adapter]] with a straight Ethernet cable and plug USB adapter to computer.
 
# Power up the 24 VDC power. Some leds should start blinking at the drive (specifily LD3 and/or LD4).
 
# Power up the 24 VDC power. Some leds should start blinking at the drive (specifily LD3 and/or LD4).
 
# Launch Granity software and:
 
# Launch Granity software and:
 
##Go to Connect tab
 
##Go to Connect tab
##Ensure that SM V2 USB adapter is selected from drowdown list called ''Communication interface device''
+
##Ensure that SM V2 USB adapter is selected from dropdown list called ''Communication interface device''
 +
##Click ''Connect to drive''
 +
##Once list of connected drives pop up, select the one you connected and click ''Open''
 +
====IONICUBE====
 +
# Wire up IONICUBE logic power (24V) supply.
 +
# Connect IONICUBE connector X1 (any of two ports) connector to [[SimpleMotion V2 USB adapter]] with a straight Ethernet cable and plug USB adapter to  computer.
 +
#Make sure that SM bus termination is set on.
 +
#*IONICUBE 4 axis board rev. 007: insert jumper to JP10 position 1 (see image [[IONI & IONICUBE user guide/Making the first Granity connection|here]]),
 +
#*IONICUBE 4 axis board rev. 009 and higher: set the switch S1 position 1 to ON (see image [[IONI & IONICUBE user guide/Making the first Granity connection|here]]), and
 +
#*IONICUBE 1X, set DIP switch S1 position 1 on).
 +
# Power up the 24 VDC power. Some leds should start blinking at the drive.
 +
# Launch Granity software and:
 +
##Go to Connect tab
 +
##Ensure that SM V2 USB adapter is selected from dropdown list called ''Communication interface device''
 
##Click ''Connect to drive''
 
##Click ''Connect to drive''
 
##Once list of connected drives pop up, select the one you connected and click ''Open''
 
##Once list of connected drives pop up, select the one you connected and click ''Open''
  
 
Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step.
 
Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step.
 +
 
==Disconnecting==
 
==Disconnecting==
To disconnect, just click '''Disconnect''' button. Before disconnecting ensure following:
+
To disconnect, just click '''Disconnect from drive''' button. Before disconnecting ensure following:
 
*Have you changed some parameters without pressing '''Apply settings''' button afterwards?
 
*Have you changed some parameters without pressing '''Apply settings''' button afterwards?
 
*Have you modified settings and wish to keep the changes? If yes, see [[#Loading and saving settings]]
 
*Have you modified settings and wish to keep the changes? If yes, see [[#Loading and saving settings]]
 +
 
==Enable or disable motor control==
 
==Enable or disable motor control==
 
Enable/disable feature sets drive in active (enabled) or inactive (disabled) state. In enabled state drive performs motor control (such as positioning) and in disabled states drive lets motor free-wheel (torque off) or brakes motor.
 
Enable/disable feature sets drive in active (enabled) or inactive (disabled) state. In enabled state drive performs motor control (such as positioning) and in disabled states drive lets motor free-wheel (torque off) or brakes motor.
Line 38: Line 55:
 
*To disable drive, click '''Disable drive''' button or Esc key from anywhere in the software
 
*To disable drive, click '''Disable drive''' button or Esc key from anywhere in the software
 
*Alternatively set logic 0 to Enable drive physical input
 
*Alternatively set logic 0 to Enable drive physical input
{{Warning|disabling drive by software is not reliable enough for emergenecy stopping. Always have hard-wired method available for emergency situations (safe toreque off switch or cut all power)}}
+
{{Machine|Disabling drive by software is not reliable enough for emergenecy stopping. Always have hard-wired method available for emergency situations ([[safe torque off]] switch or cut all power)}}
  
 
===Enabling drive===
 
===Enabling drive===
 
*To enable drive, click '''Enable drive''' buttton
 
*To enable drive, click '''Enable drive''' buttton
 
*In order to enable drive, logic 1 must be at drive physical Enable drive input
 
*In order to enable drive, logic 1 must be at drive physical Enable drive input
{{Warning|before clicking enable, ensure that no danger is caused by unexpected motor behavior (such as servo instability or runaway).}}
+
{{Machine|Before clicking enable, ensure that no danger is caused by unexpected motor behavior (such as servo instability or runaway).}}
  
 
===Verifying current enable/disable status===
 
===Verifying current enable/disable status===
Line 49: Line 66:
  
 
==Loading and saving settings==
 
==Loading and saving settings==
 +
[[File:Drive settings transfer princible.png|400px|thumb|Different locations and transfer ways of parameters between drive, Granity and file system]]
 
Drive parameters have three possible storage medias:
 
Drive parameters have three possible storage medias:
 
;Drive internal parameter memory (RAM)  
 
;Drive internal parameter memory (RAM)  
Line 58: Line 76:
 
*These parameters are automatically loaded to RAM during drive power-on
 
*These parameters are automatically loaded to RAM during drive power-on
 
*To store parameters from RAM to Flash, click '''Save settings to drive non-volatile memory''' button
 
*To store parameters from RAM to Flash, click '''Save settings to drive non-volatile memory''' button
 +
;User interface (UI)
 +
*Parameters visible on Granity user interface
 +
*Can be modified by user
 +
*UI parameters can be transferred to drive (Apply) or to file
 
;File on computer filesystem
 
;File on computer filesystem
 
*Parameters may be also stored and loaded from a file (file name ending: .drc)
 
*Parameters may be also stored and loaded from a file (file name ending: .drc)
Line 68: Line 90:
 
Some faults are clearable only by restarting drive. Restarting may be done by clicking '''Restart drive''' or by cycling 24VDC power. Restart is needed if Permanent stop status register bit is on. Note: Permanent stop bit is turned on also by changing certain parameters (not a fault).
 
Some faults are clearable only by restarting drive. Restarting may be done by clicking '''Restart drive''' or by cycling 24VDC power. Restart is needed if Permanent stop status register bit is on. Note: Permanent stop bit is turned on also by changing certain parameters (not a fault).
  
{{Warning|if drive is in enabled state during clear faults command, drive will become enabled automatically. Ensure safety before resetting faults.}}
+
{{Machine|If drive is in enabled state during clear faults command, drive will become enabled automatically. Ensure safety before resetting faults.}}
  
 
==Upgrading drive firmware==
 
==Upgrading drive firmware==
 +
See the main article [[Granity user guide/Uploading a firmware]].
  
 
==Troubleshooting==
 
==Troubleshooting==
* Check if [Argon LED status indicators] are indicating an error
+
* Check if LEDs are indicating an error (LEDs of: [[Argon user guide/LED indicators|Argon]], [[IONI & IONICUBE user guide/LED indicators|Ioni]])
* Ensure that each device in the bus has unique address selected from DIP switches
+
* Ensure that each device in the bus has unique selected ([[Setting device bus address|Argon]])
* Ensure correct interface device has been selected
+
* Ensure correct interface device has been selected from the dropdown list. If multiple choices are shown, try the other ones. If adapter is not shown, try restarting Granity.
* Ensure that bus termination DIP setting has been turned on only on the last drive in the bus
+
* Ensure that bus termination has been properly set on only on the last drive in the bus  
[[Category:Software]]
+
**[[Setting device bus address|Argon bus termination]]
[[Category:Setup guides]]
+
**For IONICUBE (4 axis) ensure that jumper in JP10 position 3 is inserted
[[Category:Granity]]
+
**For IONICUBE 1X, ensure that S1 position 1 is switched on)
[[Category:Argon]]
+
*See [[Device connection troubleshooting]]
 +
{{next|[[Granity user guide/Goals]]}}
 +
 
 +
[[Category:Granity_user_guide]]

Latest revision as of 07:59, 27 April 2017

Granityconnect.png

This tab serves following purposes:

  • Connecting and disconnecting to a drive
  • Loading and saving settings
  • Clear drive fault state
  • Enable or disable motor control
  • Restart drive
  • Upgrade firmware of the drive

Connecting[edit | edit source]

Preparations[edit | edit source]

Before connecting drive to Granity, read through Argon setup guide.

Minimum requirements for connection:

Establishing connection[edit | edit source]

Argon[edit | edit source]

  1. Connect PE of J4 connector to protective earth. After that wire 24 VDC power supply to Argon's J3 connector, however do not power up yet.
  2. Set drive address to give an bus address to the device.
  3. Connect Argon J2 (any of two ports) connector to SimpleMotion V2 USB adapter with a straight Ethernet cable and plug USB adapter to computer.
  4. Power up the 24 VDC power. Some leds should start blinking at the drive (specifily LD3 and/or LD4).
  5. Launch Granity software and:
    1. Go to Connect tab
    2. Ensure that SM V2 USB adapter is selected from dropdown list called Communication interface device
    3. Click Connect to drive
    4. Once list of connected drives pop up, select the one you connected and click Open

IONICUBE[edit | edit source]

  1. Wire up IONICUBE logic power (24V) supply.
  2. Connect IONICUBE connector X1 (any of two ports) connector to SimpleMotion V2 USB adapter with a straight Ethernet cable and plug USB adapter to computer.
  3. Make sure that SM bus termination is set on.
    • IONICUBE 4 axis board rev. 007: insert jumper to JP10 position 1 (see image here),
    • IONICUBE 4 axis board rev. 009 and higher: set the switch S1 position 1 to ON (see image here), and
    • IONICUBE 1X, set DIP switch S1 position 1 on).
  4. Power up the 24 VDC power. Some leds should start blinking at the drive.
  5. Launch Granity software and:
    1. Go to Connect tab
    2. Ensure that SM V2 USB adapter is selected from dropdown list called Communication interface device
    3. Click Connect to drive
    4. Once list of connected drives pop up, select the one you connected and click Open

Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step.

Disconnecting[edit | edit source]

To disconnect, just click Disconnect from drive button. Before disconnecting ensure following:

  • Have you changed some parameters without pressing Apply settings button afterwards?
  • Have you modified settings and wish to keep the changes? If yes, see #Loading and saving settings

Enable or disable motor control[edit | edit source]

Enable/disable feature sets drive in active (enabled) or inactive (disabled) state. In enabled state drive performs motor control (such as positioning) and in disabled states drive lets motor free-wheel (torque off) or brakes motor.

Disabling drive[edit | edit source]

  • To disable drive, click Disable drive button or Esc key from anywhere in the software
  • Alternatively set logic 0 to Enable drive physical input

Enabling drive[edit | edit source]

  • To enable drive, click Enable drive buttton
  • In order to enable drive, logic 1 must be at drive physical Enable drive input

Verifying current enable/disable status[edit | edit source]

Loading and saving settings[edit | edit source]

Different locations and transfer ways of parameters between drive, Granity and file system

Drive parameters have three possible storage medias:

Drive internal parameter memory (RAM)
  • This holds currently active set of parameters in the drive
  • These parameters are automatically fetched to the user interface every time Granity is connected to drive
  • RAM parameters are overridden by the present values of the user interface when Apply settings button is pressed
Drive internal non-volatile memory (Flash)
  • Parameters in this memory will 'stick' in drive when device is powered off
  • These parameters are automatically loaded to RAM during drive power-on
  • To store parameters from RAM to Flash, click Save settings to drive non-volatile memory button
User interface (UI)
  • Parameters visible on Granity user interface
  • Can be modified by user
  • UI parameters can be transferred to drive (Apply) or to file
File on computer filesystem
  • Parameters may be also stored and loaded from a file (file name ending: .drc)
  • To load settings, click Load settings from file and to activate these settings in drive, click Apply settings
  • To save settings currently present in the user interface to file, click Save settings to file

Clearing drive faults[edit | edit source]

If drive enters in fault state, it typically can be cleared by clicking Clear drive faults button or performing equivalent reset errors command via phyiscal IO pins.

Some faults are clearable only by restarting drive. Restarting may be done by clicking Restart drive or by cycling 24VDC power. Restart is needed if Permanent stop status register bit is on. Note: Permanent stop bit is turned on also by changing certain parameters (not a fault).


Upgrading drive firmware[edit | edit source]

See the main article Granity user guide/Uploading a firmware.

Troubleshooting[edit | edit source]

  • Check if LEDs are indicating an error (LEDs of: Argon, Ioni)
  • Ensure that each device in the bus has unique selected (Argon)
  • Ensure correct interface device has been selected from the dropdown list. If multiple choices are shown, try the other ones. If adapter is not shown, try restarting Granity.
  • Ensure that bus termination has been properly set on only on the last drive in the bus
    • Argon bus termination
    • For IONICUBE (4 axis) ensure that jumper in JP10 position 3 is inserted
    • For IONICUBE 1X, ensure that S1 position 1 is switched on)
  • See Device connection troubleshooting