Editing IONICUBE 1X connectors and pinouts
Your changes will be displayed to readers once an authorized user accepts them. (help) |
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 61: | Line 61: | ||
| 1 || class="powpin" | GND|| colspan="3" | Ground for cable shield and an optional motor holding brake coil | | 1 || class="powpin" | GND|| colspan="3" | Ground for cable shield and an optional motor holding brake coil | ||
|- | |- | ||
− | | | + | | 2|| class="outpin" |PHASE1 ||U (some motors R)||Armature +||Coil A.1 |
|- | |- | ||
− | | | + | | 3|| class="outpin" |PHASE2 ||V (some motors S)||Armature -||Coil A.2 |
|- | |- | ||
− | | | + | | 4|| class="outpin" |PHASE3 ||W (some motors T)||Armature -||Coil B.1 |
|- | |- | ||
− | | | + | | 5|| class="outpin" |PHASE4 || Not connected||Armature +||Coil B.2 |
− | + | |- | |
+ | | 6|| class="outpin" |BRAKE || colspan="3" |Optional 24V motor holding brake coil | ||
|} | |} | ||
Line 174: | Line 175: | ||
To mount in DIN rail, obtain 2 pcs of Phoenix Contact part number 1201578. Such part is available from many distributors including {{digikey|277-2296-ND}} | To mount in DIN rail, obtain 2 pcs of Phoenix Contact part number 1201578. Such part is available from many distributors including {{digikey|277-2296-ND}} | ||
{{picturebox|Ionicube1x dims.png|caption=Dimensions and mounting hole locations}}. | {{picturebox|Ionicube1x dims.png|caption=Dimensions and mounting hole locations}}. | ||
− | |||
− | |||
− |