IONI & IONICUBE user guide/Making the first Granity connection

From Granite Devices Knowledge Wiki
Jump to: navigation, search

Contents

Follow the instructions to make the first Granity connection to IONI drive.

Preparations

  1. Download and install the Granity software. Lates version is downloadable from the link: Granity software for windows (approx 15 MB)
  2. Make a wiring similar to the image below
  3. Connect IONICUBE X1 connector to SimpleMotion V2 USB adapter with a straight Ethernet cable and plug USB adapter to computer.
  4. Power up the 24 VDC power. Some leds should start blinking at the drive (more about blinking sequences).
  5. Launch Granity software and:
    1. Go to Connect tab
    2. Ensure that "SimpleMotion V2 Adapter" is selected from drowdown list called Communication interface device. (note 1)
    3. Click Connect to drive
    4. Once list of connected drives pop up, select the one you connected and click Open

Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step.

Note 1) If multiple choices are named as "SimpleMotion V2 Adapter", then try each of them to find the correct one. Also if no adapters found, try launching Granity again as the list updates only at start-up.

Ionicube granity minimum.png

Minimum connection for Granity




In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.