Differential encoders (the ones which have complementary output pairs, such as quadrature outputs A+, A-, B+ and B-) are typically designed to be driven into RS422 type differential receiver circuit. Such circuit is present in most Granite Devices drives, such as ARGON and IONI.

Line termination can be used to enhance signal quality and reliability in the differential line. Termination means adding a resistor between the differential pair wires at the end of cable. Resistance value should match the cable characteristic impedance. If not impedance is not known, safe assumption is to use 100 to 120 ohm resistors.

Incremental encoders[edit | edit source]

Encoderteriminationwiki.png

Encoder differential line termination with resistors

Serial data encoders (SSI/BiSS)[edit | edit source]

Ssi biss wiring termination large.svg

SSI/BiSS encoder with differential clock and data lines with

Is termination necessary?[edit | edit source]

If encoder cable is long, then termination may be required for stable readout of encoder. As rule of thumb, normally quadrature encoder cables shorter than 3 meters don't need termination. This might be different for serial data encoders, such as BiSS or SSI encoders because they usually carry higher frequency signals. However, if signal quality problems occur, then it is always advised to try termination as well as use of EMI suppression cores.

For calculations for termination necessity in general cases, see: http://ltxfaq.custhelp.com/app/answers/detail/a_id/1382/~/rs485-%26-rs422---when-is-termination-required%3F


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.