Latest revision | Your text | ||
Line 16: | Line 16: | ||
*Output A,B,Z 3.3 volt signals | *Output A,B,Z 3.3 volt signals | ||
*Minimum output pulse length 2 µs (requirement for receiving device to accept count rate of 1 MHz) | *Minimum output pulse length 2 µs (requirement for receiving device to accept count rate of 1 MHz) | ||
− | *Output resolution is '''divided by 4''' compared to the native resolution of the feedback device | + | *Output resolution is '''divided by 4''' compared to the native resolution of the feedback device |
;Limitations | ;Limitations | ||
Line 45: | Line 45: | ||
In addition to this, pull-up resistors may be necessary in optoisolator outputs: three 470 to 1000 ohm resistors from A-ISOLATED to 5V-ISOLATED, B-ISOLATED to 5V-ISOLATED and Z-ISOLATED to 5V-ISOLATED. The need of pull-ups depend on whether the motion controller has internal pull-up resistors or not. | In addition to this, pull-up resistors may be necessary in optoisolator outputs: three 470 to 1000 ohm resistors from A-ISOLATED to 5V-ISOLATED, B-ISOLATED to 5V-ISOLATED and Z-ISOLATED to 5V-ISOLATED. The need of pull-ups depend on whether the motion controller has internal pull-up resistors or not. | ||
− | |||
− |