Difference between revisions of "VSD-E/XE grounding"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
 
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
[[File:VSDE grounding scheme.png|thumb|Internal power and ground connections of VSD-E and XE]]
 
[[File:VSDE grounding scheme.png|thumb|Internal power and ground connections of VSD-E and XE]]
[[Category:Hardware]]
+
[[VSD-E and VSD-XE]] internal power wiring illustrated.
[[Category:Setup guides]]
+
;Signals
 +
* A,B,C and D - the motor output phases
 +
* GND - ground or 0V potential
 +
* FG - frame ground (cable shields connect here)
 +
* 12V - logic supply voltage
 +
* HV+ - high voltage supply of 12-160VDC
 +
==Frame ground==
 +
FG is internally connected to GND via RC circuit. The capacitor in the circuit passes high frequency interference to ground and resistor prevents static voltage build-up.
 +
[[Category:VSD-E/XE user guide]]

Latest revision as of 22:00, 9 August 2013

Internal power and ground connections of VSD-E and XE

VSD-E and VSD-XE internal power wiring illustrated.

Signals
  • A,B,C and D - the motor output phases
  • GND - ground or 0V potential
  • FG - frame ground (cable shields connect here)
  • 12V - logic supply voltage
  • HV+ - high voltage supply of 12-160VDC

Frame ground[edit | edit source]