==Frame ground== | ==Frame ground== | ||
FG is internally connected to GND via RC circuit. The capacitor in the circuit passes high frequency interference to ground and resistor prevents static voltage build-up. | FG is internally connected to GND via RC circuit. The capacitor in the circuit passes high frequency interference to ground and resistor prevents static voltage build-up. | ||
− | [[Category: | + | [[Category:VSD-E/XE user guide]] |
− | + |
Latest revision as of 22:00, 9 August 2013
VSD-E and VSD-XE internal power wiring illustrated.
- Signals
- A,B,C and D - the motor output phases
- GND - ground or 0V potential
- FG - frame ground (cable shields connect here)
- 12V - logic supply voltage
- HV+ - high voltage supply of 12-160VDC
Frame ground[edit | edit source]
FG is internally connected to GND via RC circuit. The capacitor in the circuit passes high frequency interference to ground and resistor prevents static voltage build-up.