Difference between revisions of "Motion fault limit paremeter"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
 
(3 intermediate revisions by the same user not shown)
Line 18: Line 18:
 
# Set threshold to low starting value such as 500
 
# Set threshold to low starting value such as 500
 
# Give settings a try and observe if motion fault occurs in normal use
 
# Give settings a try and observe if motion fault occurs in normal use
# If fault occurs, increase threshold until it stops happening (one may add some safety headroom after this point is reached to increase margin for rare errors)
+
# If unwanted fault occurs, increase threshold and go to step 2
 +
# Add some safety headroom (10-50%) to the threshold to increase margin for rare errors
 
# Simulate some fault cases to ensure that fault triggers properly (such as disconnect feedback or block motion). If fault doesn't occur reliably, decrease threshold.
 
# Simulate some fault cases to ensure that fault triggers properly (such as disconnect feedback or block motion). If fault doesn't occur reliably, decrease threshold.
 +
[[Category:VSD-E/XE user guide]]
 +
[[Category:Granity parameters]]
 +
===Disabling motion fault===
 +
If motion fault is not needed or can't be configured to operate properly, one can disable it by setting threshold value to 0.

Latest revision as of 22:01, 9 August 2013

The parameter called motion fault limit controls a safety faulting mechanism of GD servo drives.

Usage[edit | edit source]

Motion fault attempts to detect incorrect motor behavior and sets drive in fault state (and stop driving motor) in case of abnormal motion condition. The motion fault will help to detect following fault scenarios:

  • DC motor runaway when feedback is lost
  • Motion blocked by obstacle (can react faster than following/tracking error fault)
  • Detect stall of stepping motor

How it works[edit | edit source]

Motion fault monitors three variables to determine fault:

  • Actual velocity
  • Time
  • Output torque/current

Drive activates fault if output current is greater than set threshold value for over 0.2 second period and simultaneously velocity stays below a fixed threshold.

Parameters[edit | edit source]

Motion fault has only one changeable parameter: threshold. The threshold value controls the current level which must be exceeded to activate 0.2 second timer and velocity monitor.

Finding correct value[edit | edit source]

Correct value can be found by experimenting.

  1. Set threshold to low starting value such as 500
  2. Give settings a try and observe if motion fault occurs in normal use
  3. If unwanted fault occurs, increase threshold and go to step 2
  4. Add some safety headroom (10-50%) to the threshold to increase margin for rare errors
  5. Simulate some fault cases to ensure that fault triggers properly (such as disconnect feedback or block motion). If fault doesn't occur reliably, decrease threshold.

Disabling motion fault[edit | edit source]

If motion fault is not needed or can't be configured to operate properly, one can disable it by setting threshold value to 0.