Difference between revisions of "Argon user guide/Power supply safe discharging"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(2 intermediate revisions by the same user not shown) | |||
Line 6: | Line 6: | ||
# Remove power from J4 connector (both L and N lines). This can be done for example by unplugging the power cord from wall socket where the power comes from. | # Remove power from J4 connector (both L and N lines). This can be done for example by unplugging the power cord from wall socket where the power comes from. | ||
# Wait at least 3 minutes after de-energization to allow capacitor voltage discharge. | # Wait at least 3 minutes after de-energization to allow capacitor voltage discharge. | ||
− | # Measure a DC voltage between VN and VP terminals of J4 connector with a multimeter rated up to 600 VDC. Voltage has discharged if VN-VP voltage is less than | + | # Measure a DC voltage between VN and VP terminals of J4 connector with a multimeter rated at least up to 600 VDC as the worst case drive internal HV voltage may be over 400 VDC. '''Voltage has been successfully discharged if VN-VP voltage is less than 5 VDC.''' |
{{electricshock|If DC voltage between VN and VP terminals of J4 connector is above 20 VDC after 3 minutes of de-energization, drive has internal failure of discharging circuity. In such case danger may be present even after weeks of wait. Contact your supplier first for further assistance before continuing servicing.}} | {{electricshock|If DC voltage between VN and VP terminals of J4 connector is above 20 VDC after 3 minutes of de-energization, drive has internal failure of discharging circuity. In such case danger may be present even after weeks of wait. Contact your supplier first for further assistance before continuing servicing.}} | ||
Discharging 24 VDC supply does happen instantly after 24 V has been removed. However, this does not affect AC side discharge in any way. | Discharging 24 VDC supply does happen instantly after 24 V has been removed. However, this does not affect AC side discharge in any way. | ||
− | + | ||
− | [[Category: | + | [[Category:Argon_user_guide]] |
Latest revision as of 13:17, 7 April 2016
Power supplies and drives have capacitors that store electricity even when power supply has been disconnected from the power network. This poses electric shock hazard when touching a device, or its wiring, that has been recently unplugged from the power line.
Safely discharging Argon drive[edit | edit source]
Argon (servo drive) has internal power supply bleeding resistor that will discharge the capacitors during 5 minutes after AC power has been removed.
To safely discharge Argon voltages:
- Remove power from J4 connector (both L and N lines). This can be done for example by unplugging the power cord from wall socket where the power comes from.
- Wait at least 3 minutes after de-energization to allow capacitor voltage discharge.
- Measure a DC voltage between VN and VP terminals of J4 connector with a multimeter rated at least up to 600 VDC as the worst case drive internal HV voltage may be over 400 VDC. Voltage has been successfully discharged if VN-VP voltage is less than 5 VDC.
If DC voltage between VN and VP terminals of J4 connector is above 20 VDC after 3 minutes of de-energization, drive has internal failure of discharging circuity. In such case danger may be present even after weeks of wait. Contact your supplier first for further assistance before continuing servicing. |
Discharging 24 VDC supply does happen instantly after 24 V has been removed. However, this does not affect AC side discharge in any way.