Difference between revisions of "IONI hardware revisions"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(Tag: VisualEditor) |
(Tag: VisualEditor) |
||
Line 16: | Line 16: | ||
** No practical effect for end user | ** No practical effect for end user | ||
* Changed GPI1,2,3 series resistors from 220 ohm to 68 ohm | * Changed GPI1,2,3 series resistors from 220 ohm to 68 ohm | ||
+ | ** Improve clock signal strength with BiSS and SSI encoders | ||
|- | |- | ||
| 1.2017 | | 1.2017 | ||
Line 21: | Line 22: | ||
|V6|| | |V6|| | ||
* Changed GPI1,2,3 series resistors from 220 ohm to 68 ohm | * Changed GPI1,2,3 series resistors from 220 ohm to 68 ohm | ||
+ | ** Improve clock signal strength with BiSS and SSI encoders | ||
|- | |- | ||
| 1.2017 || IONI, IONI Pro, IONI Pro HC || V29 | | 1.2017 || IONI, IONI Pro, IONI Pro HC || V29 |
Revision as of 16:04, 14 February 2017
List IONI drive hardware revisions and changes.
Release date | Models | PCB version | Component configuration | Changes |
---|---|---|---|---|
2015 | IONI, IONI Pro, IONI Pro HC | V26 | Initial version | Initial release |
1.2017 | IONI, IONI Pro | V26 | V6 |
|
1.2017 | IONI Pro HC | V26 | V6 |
|
1.2017 | IONI, IONI Pro, IONI Pro HC | V29 | V6 |
|