Difference between revisions of "IONI hardware revisions"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(Tag: VisualEditor) |
(Tag: VisualEditor) |
||
Line 5: | Line 5: | ||
|- | |- | ||
! Release date !! Models !! PCB version | ! Release date !! Models !! PCB version | ||
− | !Component configuration!! Changes | + | !Component configuration!! Changes & Impact |
!How to identify | !How to identify | ||
Line 38: | Line 38: | ||
|V6|| | |V6|| | ||
* New PCB revision with reduced encoder to current sense crosstalk | * New PCB revision with reduced encoder to current sense crosstalk | ||
− | ** In high inductance motors may reduced motor audible noise | + | ** In high inductance motors may reduced motor audible noise. Crosstalk is reduced by approximately 10 dB. |
− | + | ||
* Added 3300 ohm 5V pull-up resistor to GPI5 input | * Added 3300 ohm 5V pull-up resistor to GPI5 input | ||
** Originally GPI5 was pulled up by >30kOhm resistor to 3.3V | ** Originally GPI5 was pulled up by >30kOhm resistor to 3.3V |
Revision as of 22:16, 14 February 2017
List IONI drive hardware revisions and changes.
Release date | Models | PCB version | Component configuration | Changes & Impact | How to identify |
---|---|---|---|---|---|
5.2015 | IONI, IONI Pro, IONI Pro HC | V26 | Initial version | Initial release |
|
1.2017 | IONI, IONI Pro | V26 | V6 |
|
|
1.2017 | IONI Pro HC | V26 | V6 |
|
|
1.2017 | IONI, IONI Pro, IONI Pro HC | V29 | V6 |
|
|