Difference between revisions of "ATOMI connectors and pinouts"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(→X2 - Main setpoint connector) |
|||
Line 58: | Line 58: | ||
| 7||4|| class="inpin" |HSIN2_Y||Direction input Y||8||17|| class="inpin" |AUX_IN||Auxilary transistor input | | 7||4|| class="inpin" |HSIN2_Y||Direction input Y||8||17|| class="inpin" |AUX_IN||Auxilary transistor input | ||
|- | |- | ||
− | | 9||5|| class="inpin" |HSIN1_Y||Pulse/step input Y||10||18|| class="powpin" |GND|| rowspan="8" |Ground | + | | 9||5|| class="inpin" |HSIN1_Y||Pulse/step input Y||10||18|| class="powpin" |GND|| rowspan="8" |Ground / 0 V |
|- | |- | ||
| 11||6|| class="inpin" |HSIN2_Z||Direction input Z||12||19|| class="powpin" |GND | | 11||6|| class="inpin" |HSIN2_Z||Direction input Z||12||19|| class="powpin" |GND |
Revision as of 10:32, 3 April 2017
Contents
Legend
Color |
---|
Supply pin |
Input pin |
Output pin |
MX, MY, MZ, MA - Motor and encoder connectors
Pin number | Signal name | Usage |
---|---|---|
1 | SW | Limit switch, shared for both directions |
2 | CHC / Homeswitch | Encoder channel C (index) / homeswitch |
3 | CHB | Encoder channel B |
4 | CHA | Encoder channel A |
5 | +5 V | 5 V supply voltage to encoder |
6 | GND | Encoder supply ground / 0 V |
7 | PH4 | Motor phase 4 |
8 | W / PH3 | Motor phase 3 / Servo W |
9 | V / PH2 | Motor phase 2 / Servo V |
10 | U / PH1 | Motor phase 1 / Servo U |
X1 - Granity and SimpleMotion V2 connector
X2 - Main setpoint connector
Connect X2 only to 3.3V or 5V logic systems. |
X2 is main control and setpoint signal port consisting Global Enable input signal, Global Fault output signal, pulse and direction/PWM setpoint inputs and digital outputs for servo ready signals. X2 is directly wired to conform most common parallel port style pulse & direction CNC controllers.
Pin number in header | Pin number in D25 cable | Signal name | Typical usage | Pin number in header | Pin number in D25 cable | Signal name | Typical usage | |
---|---|---|---|---|---|---|---|---|
1 | 1 | ENABLE | Enable all axis (with or without chargepump) | 2 | 14 | Homing | Start homing for all axis | |
3 | 2 | HSIN2_X | Direction input X | 4 | 15 | Global_GPO3 | Global fault output | |
5 | 3 | HSIN1_X | Pulse/step input X | 6 | 16 | PWM2ANA | PWM to analogue converter input | |
7 | 4 | HSIN2_Y | Direction input Y | 8 | 17 | AUX_IN | Auxilary transistor input | |
9 | 5 | HSIN1_Y | Pulse/step input Y | 10 | 18 | GND | Ground / 0 V | |
11 | 6 | HSIN2_Z | Direction input Z | 12 | 19 | GND | ||
13 | 7 | HSIN1_Z | Pulse/step input Z | 14 | 20 | GND | ||
15 | 8 | HSIN2_A | Direction input A | 16 | 21 | GND | ||
17 | 9 | HSIN1_A | Pulse/step input A | 18 | 22 | GND | ||
19 | 10 | GPO1_X | X axis servo ready signal | 20 | 23 | GND | ||
21 | 11 | GPO1_Y | Y axis servo ready signal | 22 | 24 | GND | ||
23 | 12 | GPO1_Z | Z axis servo ready signal | 24 | 25 | GND | ||
25 | 13 | GPO1_A | A axis servo ready signal | 26 | N/A | Not connected |
X3 - Additional setpoint and IO connector
Connect X3 only to 3.3V or 5V logic systems. |
X3 is a second control and setpoint signal port addition to X2. X3 consists of analog setpoint signal inputs and additional digital I/O.
Pin number in header | Pin number in D25 cable | Signal name | Typical usage | Pin number in header | Pin number in D25 cable | Signal name | Typical usage | |
---|---|---|---|---|---|---|---|---|
1 | 1 | GND | GND / 0 V | 2 | 14 | +5V | +5 V supply | |
3 | 2 | GND | GND / 0 V | 4 | 15 | Global_IO4 | Global IO 4 | |
5 | 3 | AUX_OUT | Buffered output for AUX_IN | 6 | 16 | ANA_OUT | PWM to analogue converter output, 0..5 V | |
7 | 4 | X_GPI2 | Enable positive X travel | 8 | 17 | X_GPI3 | Enable negative X travel | |
9 | 5 | X_GPO4 | X position within limits | 10 | 18 | X_GPO2 | X tracking error | |
11 | 6 | X_ANAIN | X analogue setpoint input | 12 | 19 | Y_GPI2 | Enable positive Y travel | |
13 | 7 | Y_GPI3 | Enable negative Y travel | 14 | 20 | Y_GPO4 | Y position within limits | |
15 | 8 | Y_GPO2 | Y tracking error | 16 | 21 | Y_ANAIN | Y analogue setpoint input | |
17 | 9 | Z_GPI2 | Enable positive Z travel | 18 | 22 | Z_GPI3 | Enable positive Z travel | |
19 | 10 | Z_GPO4 | Z position within limits | 20 | 23 | Z_GPO2 | Z tracking error | |
21 | 11 | Z_ANAIN | Z analogue setpoint input | 22 | 24 | A_GPI2 | Enable positive A travel | |
23 | 12 | A_GPI3 | Enable negative A travel | 24 | 25 | A_GPO4 | A position within limits | |
25 | 13 | A_GPO2 | A tracking error | 26 | N/A | A_ANAIN | A analogue setpoint input |
X4 - Power input and STO connector
X4 is three pin wire terminal for HV DC bus supply and Safe torque off.
Pin number | Signal name | Usage | Electrical |
---|---|---|---|
1 | GND | Ground | |
2 | STO | Safe torque off | 3.3 - 48 V |
3 | HV+ | Motor power supply, HV DC bus | 12 - 48 V |
JP1 to JP4 - Encoder passthrough connector
JP1 to JP4 are pin headers for external encoder use.
Pin number | Signal name | Usage |
---|---|---|
1 | +5V | +5 V supply |
2 | CHA | Encoder channel A |
3 | GND | GND / 0 V |
4 | CHB | Encoder channel B |
5 | GND | GND / 0 V |
6 | CHC | Encoder channel C |