Feature comparison
| Feature | ATOMI DeepStepTM | ATOMI Standard | ATOMI Advanced |
|---|---|---|---|
| Motor support | |||
| Stepper motor, open loop | Yes | Yes | Yes |
| Stepper motor, sensorless closed loop | Yes | Yes | Yes |
| Stepper motor, sensored closed loop | - | Yes | Yes |
| AC/DC servo motor | - | Yes | Yes |
| Feedback support | |||
| Quadrature encoder | - | Yes | Yes |
| Setpoint support | |||
| SimpleMotionV2 | Yes | Yes | Yes |
| Step/dir | Yes | Yes | Yes |
| PWM, with or without direction bit | - | - | Yes |
| Analog | - | - | Yes 1 |
| Operation mode support | |||
| Position mode | Yes | Yes | Yes |
| Velocity mode | - | - | Yes |
| Torque mode | - | - | Yes |
| Other features | |||
| Acceleration and velocity feedforward | - | - | Yes |
| Auto setup | Yes | Yes | Yes |
| Homing | - | - | Yes |
| VFD out | Yes | Yes | Yes |
1) ±10 V analog setpoint requires external circuitry. The voltage range of ATOMI analog inputs is 0 - 3.3 V.