# If fault occurs, increase threshold until it stops happening (one may add some safety headroom after this point is reached to increase margin for rare errors) | # If fault occurs, increase threshold until it stops happening (one may add some safety headroom after this point is reached to increase margin for rare errors) | ||
# Simulate some fault cases to ensure that fault triggers properly (such as disconnect feedback or block motion). If fault doesn't occur reliably, decrease threshold. | # Simulate some fault cases to ensure that fault triggers properly (such as disconnect feedback or block motion). If fault doesn't occur reliably, decrease threshold. | ||
+ | [[Category:Setup guides]] |
Revision as of 09:51, 17 July 2012
The parameter called motion fault limit controls a safety faulting mechanism of GD servo drives.
Usage
Motion fault attempts to detect incorrect motor behavior and sets drive in fault state (and stop driving motor) in case of abnormal motion condition. The motion fault will help to detect following fault scenarios:
- DC motor runaway when feedback is lost
- Motion blocked by obstacle (can react faster than following/tracking error fault)
- Detect stall of stepping motor
How it works
Motion fault monitors three variables to determine fault:
- Actual velocity
- Time
- Output torque/current
Drive activates fault if output current is greater than set threshold value for over 0.2 second period and simultaneously velocity stays below a fixed threshold.
Parameters
Motion fault has only one changeable parameter: threshold. The threshold value controls the current level which must be exceeded to activate 0.2 second timer and velocity monitor.
Finding correct value
Correct value can be found by experimenting.
- Set threshold to low starting value such as 500
- Give settings a try and observe if motion fault occurs in normal use
- If fault occurs, increase threshold until it stops happening (one may add some safety headroom after this point is reached to increase margin for rare errors)
- Simulate some fault cases to ensure that fault triggers properly (such as disconnect feedback or block motion). If fault doesn't occur reliably, decrease threshold.