This dialog serves following purposes: | This dialog serves following purposes: | ||
− | * Connecting and disconnecting to drive | + | * Connecting and disconnecting to a drive |
* Loading and saving settings | * Loading and saving settings | ||
* Clear drive fault state | * Clear drive fault state | ||
+ | * Enable or disable motor control | ||
+ | * Restart drive | ||
+ | * Upgrade firmware of the drive | ||
==Connecting== | ==Connecting== | ||
===Preparations=== | ===Preparations=== | ||
− | In order to establish a connection from PC to drive, ensure that drive is wired properly. Minimum requirements for connection: | + | In order to establish a connection from PC to drive, ensure that drive is wired properly. |
− | * Argon drive | + | |
+ | Minimum requirements for connection: | ||
+ | * [[Argon (servo drive)]] | ||
* 24VDC logic power applied to drive | * 24VDC logic power applied to drive | ||
* Drive connected to PC via RS485 interface (such as SimpleMotion V2 USB adapter) | * Drive connected to PC via RS485 interface (such as SimpleMotion V2 USB adapter) | ||
Line 12: | Line 17: | ||
[kuva] | [kuva] | ||
===Establishing connection=== | ===Establishing connection=== | ||
− | + | ===Preparations=== | |
− | # | + | # Connect PE of [[Argon_wiring#J3_24V_power_and_motor_brake_port|J4 connector]] to protective earth. After that wire 24 VDC power supply to Argon's [[Argon_wiring#J3_24V_power_and_motor_brake_port|J3 connector]], however do not power up yet. |
− | # | + | # Set Argon DIP switches to give an bus address to the device. |
− | # | + | # Connect Argon J2.1 connector to [[SimpleMotion V2 USB adapter]] with a straight Ethernet cable and plug USB adapter to computer. |
+ | # Power up the 24 VDC power. Some leds should start blinking at the drive (specifily LD3 and/or LD4). | ||
+ | # Launch Granity software and: | ||
+ | ##Go to Connect tab | ||
+ | ##Ensure that SM V2 USB adapter is selected from drowdown list called ''Communication interface device'' | ||
+ | ##Click ''Connect to drive'' | ||
+ | ##Once list of connected drives pop up, select the one you connected and click ''Open'' | ||
+ | |||
+ | Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step. | ||
+ | |||
==Troubleshooting== | ==Troubleshooting== | ||
− | * Check if [ | + | * Check if [Argon LED status indicators] are indicating an error |
− | * | + | * Ensure that each device in the bus has unique address selected from DIP switches |
* Ensure correct interface device has been selected | * Ensure correct interface device has been selected | ||
* Ensure that bus termination DIP setting has been turned on only on the last drive in the bus | * Ensure that bus termination DIP setting has been turned on only on the last drive in the bus |
Revision as of 21:15, 28 December 2012
This dialog serves following purposes:
- Connecting and disconnecting to a drive
- Loading and saving settings
- Clear drive fault state
- Enable or disable motor control
- Restart drive
- Upgrade firmware of the drive
Contents
Connecting
Preparations
In order to establish a connection from PC to drive, ensure that drive is wired properly.
Minimum requirements for connection:
- Argon (servo drive)
- 24VDC logic power applied to drive
- Drive connected to PC via RS485 interface (such as SimpleMotion V2 USB adapter)
- Drive address DIP switches configured to give an unique address for drive
[kuva]
Establishing connection
Preparations
- Connect PE of J4 connector to protective earth. After that wire 24 VDC power supply to Argon's J3 connector, however do not power up yet.
- Set Argon DIP switches to give an bus address to the device.
- Connect Argon J2.1 connector to SimpleMotion V2 USB adapter with a straight Ethernet cable and plug USB adapter to computer.
- Power up the 24 VDC power. Some leds should start blinking at the drive (specifily LD3 and/or LD4).
- Launch Granity software and:
- Go to Connect tab
- Ensure that SM V2 USB adapter is selected from drowdown list called Communication interface device
- Click Connect to drive
- Once list of connected drives pop up, select the one you connected and click Open
Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step.
Troubleshooting
- Check if [Argon LED status indicators] are indicating an error
- Ensure that each device in the bus has unique address selected from DIP switches
- Ensure correct interface device has been selected
- Ensure that bus termination DIP setting has been turned on only on the last drive in the bus