Difference between revisions of "IONICUBE 1X electrical specifications"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(→Power supply) |
(→Power supply) |
||
(One intermediate revision by the same user not shown) | |||
Line 29: | Line 29: | ||
! Supply<sup>1</sup> !! Input voltage !! Input current typ !! Input current max | ! Supply<sup>1</sup> !! Input voltage !! Input current typ !! Input current max | ||
|- | |- | ||
− | | Logic power || 24 VDC +/- 10% || 0.1 - 0.3 A || | + | | Logic power || |
+ | Two variants of IONICUBE are available with different logic voltage specification: | ||
+ | * IONICUBE 1X: 24 VDC +/- 10% | ||
+ | * IONICUBE 1X WIDE: 22 - 50 VDC | ||
+ | How to tell which one I have? See [[Identifying hardware model and version]]. | ||
+ | || 0.1 - 0.3 A || 1 A (can occur when driving motor holding brakes or external relays) | ||
|- | |- | ||
− | | Motor power || 5 - | + | | Motor power || 5 - 56 VDC<sup>2</sup> ||colspan=2| Equal to current consumption of on-board IONI drive |
|} | |} | ||
− | <sup>1</sup>) Both logic and motor supplies are required. | + | <sup>1</sup>) Both logic and motor supplies are required. With WIDE logic supply version it is possible to eliminate the logic power supply and supply HV and logic voltage from a single 24-50 VDC supply. |
<sup>2</sup>) Possible to use from 5 VDC upwards, however short circuit protection feature of IONI drive is lost below 12 VDC. | <sup>2</sup>) Possible to use from 5 VDC upwards, however short circuit protection feature of IONI drive is lost below 12 VDC. |
Latest revision as of 22:02, 3 March 2016
Mechanical[edit | edit source]
Property | Value | Units |
---|---|---|
Dimensions (including IONI drives) | 87 × 44 × 59 (W×H×D) | mm |
Weight | 0.15 | kg |
Drawings | See here |
Environment[edit | edit source]
Property | Value | Units |
---|---|---|
Operating temperature | 10-70 | °C |
Storage temperature | -30-90 | °C |
Humidity | 0-95 non-condensing | % |
Power supply[edit | edit source]
Supply1 | Input voltage | Input current typ | Input current max |
---|---|---|---|
Logic power |
Two variants of IONICUBE are available with different logic voltage specification:
How to tell which one I have? See Identifying hardware model and version. |
0.1 - 0.3 A | 1 A (can occur when driving motor holding brakes or external relays) |
Motor power | 5 - 56 VDC2 | Equal to current consumption of on-board IONI drive |
1) Both logic and motor supplies are required. With WIDE logic supply version it is possible to eliminate the logic power supply and supply HV and logic voltage from a single 24-50 VDC supply.
2) Possible to use from 5 VDC upwards, however short circuit protection feature of IONI drive is lost below 12 VDC.
Regenerative resistor[edit | edit source]
Property | Value | Units |
---|---|---|
On-board resistor | none | |
Maximum current for external resistor | 8 (continuous), 15 (peak, max 0.5 seconds) | A |
Minimum allowed external resistance @ 48 VDC supply | 4 | Ω |
Minimum allowed external resistance @ 24 VDC supply | 2.5 | Ω |
Resistor power dissipation | 0-1000¹ | W |
¹) Power dissipation depends on how much system's kinetic energy is directed to the resistor. In typical applications, the dissipation is in range of 10W to 100W.