Difference between revisions of "ATOMI device model comparison"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
= Feature comparison =
 
= Feature comparison =
 
{| class="wikitable"
 
{| class="wikitable"
! Feature !! ATOMI DeepStep<sup>TM</sup> !! ATOMI Standard !! ATOMI Advanced
+
! Feature !! ATOMI DeepStep™ !! ATOMI Standard !! ATOMI Advanced
 
|-
 
|-
 
| colspan="4" |'''Motor support'''
 
| colspan="4" |'''Motor support'''
Line 16: Line 16:
 
|-
 
|-
 
| Quadrature encoder || - || Yes || Yes
 
| Quadrature encoder || - || Yes || Yes
|-
 
| Hall sensors || - || - || -
 
|-
 
| Serial encoders || - || - || -
 
 
|-
 
|-
 
| colspan="4" |'''Setpoint support'''
 
| colspan="4" |'''Setpoint support'''
Line 30: Line 26:
 
|-
 
|-
 
| Analog || - || - || Yes <sup>1</sup>
 
| Analog || - || - || Yes <sup>1</sup>
|-
 
|Quadrature
 
| -
 
| -
 
| -
 
 
|-
 
|-
 
| colspan="4" |'''Operation mode support'''
 
| colspan="4" |'''Operation mode support'''
Line 56: Line 47:
 
|}
 
|}
  
<sup>1</sup>) ±10 V analog setpoint requires external circuitry. ATOMI analog inputs are 0 - 3.3 V.
+
<sup>1</sup>) ±10 V analog setpoint requires external circuitry. The voltage range of ATOMI analog inputs is 0 - 3.3 V.
  
 
[[Category:Work_in_progress_pages]]
 
[[Category:Work_in_progress_pages]]

Latest revision as of 12:11, 7 June 2017

Feature comparison[edit | edit source]

Feature ATOMI DeepStep™ ATOMI Standard ATOMI Advanced
Motor support
Stepper motor, open loop Yes Yes Yes
Stepper motor, sensorless closed loop Yes Yes Yes
Stepper motor, sensored closed loop - Yes Yes
AC/DC servo motor - Yes Yes
Feedback support
Quadrature encoder - Yes Yes
Setpoint support
SimpleMotionV2 Yes Yes Yes
Step/dir Yes Yes Yes
PWM, with or without direction bit - - Yes
Analog - - Yes 1
Operation mode support
Position mode Yes Yes Yes
Velocity mode - - Yes
Torque mode - - Yes
Other features
Acceleration and velocity feedforward - - Yes
Auto setup Yes Yes Yes
Homing - - Yes
VFD out Yes Yes Yes

1) ±10 V analog setpoint requires external circuitry. The voltage range of ATOMI analog inputs is 0 - 3.3 V.