Line 8: Line 8:
 
#Move axis to '''offset position'''. In practice user can enter a position value to drive where axis is driven after all previous homing functions are done.
 
#Move axis to '''offset position'''. In practice user can enter a position value to drive where axis is driven after all previous homing functions are done.
 
#Set absolute position '''travel limits''' (soft limits). User may also set upper & lower bounds for position [[Setpoint signal|setpoint]] to possibly elimiate the need of axis limit switches.
 
#Set absolute position '''travel limits''' (soft limits). User may also set upper & lower bounds for position [[Setpoint signal|setpoint]] to possibly elimiate the need of axis limit switches.
 +
 +
Homing is configurable through drive configuration software. The homing sequence can be saved in the drive and can be set to start automatically after power-on or user "start homing" command.
  
 
==See also==
 
==See also==
 
*[[Hard-stop homing]]
 
*[[Hard-stop homing]]
 
[[Category:Glossary]]
 
[[Category:Glossary]]

Revision as of 14:33, 7 August 2013

Example video of hard-stop homing with VSD-XE drive (and some random motion with absolue positioning).
Homing is a method for acquiring the absolute zero position of a mechanical axis to a known absolute position.

For example if linear axis is equipped with an incremetal feedback device, then position of the axis is not known by the machine after system power-on. To acquire absolute position, axis must be driven to known point (home point) where the position counter is zeroed.

Homing methods

Most of Granite Devices drives support homing axis by comibining different optional motion elements as a sequence:

  1. Move axis to search a home switch or mechanical end of travel (a.k.a. hard-stop homing), direction and speed of motion is selectable.
  2. Move axis to search feedback device index pulse. Index pulse provides very high position repeatability. Direction is selectable.
  3. Move axis to offset position. In practice user can enter a position value to drive where axis is driven after all previous homing functions are done.
  4. Set absolute position travel limits (soft limits). User may also set upper & lower bounds for position setpoint to possibly elimiate the need of axis limit switches.

Homing is configurable through drive configuration software. The homing sequence can be saved in the drive and can be set to start automatically after power-on or user "start homing" command.