|  AXT|| Axis type & units  || ||
+
|  AXT|| Axis type & units  || Select axis type and real world units used || Choose your mechanical axis type here. AXT and AXS affect only the unit conversion of Granity parameters (such as accel/velocity limit unit conversions), no effect on drive operation.
 
|-
 
|-
|  AXS|| Axis scale || ||
+
|  AXS|| Axis scale || Set axis travel per motor revolution || Determine how much your axis moves per revolution and enter it here. I.e. if you have selected ''Linear[mm]'' as AXT, then calculate and enter how many millimeters axis moves per revolution. AXT and AXS affect only the unit conversion of Granity parameters (such as accel/velocity limit unit conversions), no effect on drive operation.
 
|}
 
|}
 
+
===Motor parameters===
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
 
! Short [[GUI]] name !! [[GUI]] name !! Description !! How to use
 
! Short [[GUI]] name !! [[GUI]] name !! Description !! How to use
 
|-
 
|-
| MT || Motor type || ||
+
| MT || Motor type || Motor type to be driven  || Choose your motor type
 
|-
 
|-
 
| MCC || Continuous current limit || ||
 
| MCC || Continuous current limit || ||

Revision as of 18:55, 14 August 2013

The Machine tab serves following purposes:

  • Choose axis type (linear/rotary) and its scale
  • Set motor type and properties
  • Set feedback device types and properties

Parameters

Axis mechanics

Short GUI name GUI name Description How to use
AXT Axis type & units Select axis type and real world units used Choose your mechanical axis type here. AXT and AXS affect only the unit conversion of Granity parameters (such as accel/velocity limit unit conversions), no effect on drive operation.
AXS Axis scale Set axis travel per motor revolution Determine how much your axis moves per revolution and enter it here. I.e. if you have selected Linear[mm] as AXT, then calculate and enter how many millimeters axis moves per revolution. AXT and AXS affect only the unit conversion of Granity parameters (such as accel/velocity limit unit conversions), no effect on drive operation.

Motor parameters

Short GUI name GUI name Description How to use
MT Motor type Motor type to be driven Choose your motor type
MCC Continuous current limit
MMC Peak current limit
MR Coil resistance
ML Coil inductance
MTC Thermal time constant
Short GUI name GUI name Description How to use
FBD Feedback device
FBR Feedback device resolution
FBI Invert feedback direction
FBH Hall sensors


Short GUI name GUI name Description How to use