Difference between revisions of "Argon user guide/Power supply safe discharging"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
Line 9: Line 9:
  
 
Discharging 24 VDC supply does happen instantly after 24 V has been removed. However, this does not affect AC side discharge in any way.
 
Discharging 24 VDC supply does happen instantly after 24 V has been removed. However, this does not affect AC side discharge in any way.
[[Category::Setup guides]]
+
[[Category:Setup guides]]
[[Category::Argon]]
+
[[Category:Argon]]

Revision as of 12:25, 17 December 2012

float

Power supplies and drives have capacitors that store electricity even when power supply has been disconnected from the power network. This poses electric shock hazard when touching a device that has been just unplugged from the power line.

Safely discharging Argon drive

Argon (servo drive) has internal power supply bleeding resistor that will discharge the capacitors during 5 minutes after AC power has been removed.

To safely discharge Argon voltages:

  1. Remove AC power (both L and N lines). This can be done for example by unplugging the power cord from wall socket where the power comes from.
  2. Wait 5 minutes after removing AC to allow capacitor voltage discharge.

Discharging 24 VDC supply does happen instantly after 24 V has been removed. However, this does not affect AC side discharge in any way.