Difference between revisions of "Argon user guide/J5 connector electrical interfacing"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
Line 2: | Line 2: | ||
==Pin electrical categories=== | ==Pin electrical categories=== | ||
===Supply=== | ===Supply=== | ||
− | Supply pins output a regulated 5V voltage to external circuits | + | Supply pins output a regulated 5V voltage to external circuits. GND pin is tied to J3 connector V- terminal. |
+ | |||
+ | ;Supply ratings | ||
+ | *Output voltage 4.9-5.1 V typ | ||
+ | *Maximum continuous load 500 mA | ||
{{Caution|Never connect multiple supply outputs parallel. Supply output may be connected only current consuming circuity to prevent current injection to the supply port.}} | {{Caution|Never connect multiple supply outputs parallel. Supply output may be connected only current consuming circuity to prevent current injection to the supply port.}} |
Revision as of 22:17, 13 June 2013
This article explains the internal circuity behind J5 connector of Argon servo drive.
Contents
Pin electrical categories=
Supply
Supply pins output a regulated 5V voltage to external circuits. GND pin is tied to J3 connector V- terminal.
- Supply ratings
- Output voltage 4.9-5.1 V typ
- Maximum continuous load 500 mA
Never connect multiple supply outputs parallel. Supply output may be connected only current consuming circuity to prevent current injection to the supply port. |
High speed digital input
HSIN is differential digital input capable of receiving digital signals up to 4 MHz.
- Input ratings
- Maximum voltage to +/- pins referenced to GND: -0.5 to 6V. Nominal 3.3 or 5.0V.
- Maximum injected current +/- 10 mA
- Wiring when driving using differential source
- Positive (+) inputs: to positive outputs of source
- Negative (-) inputs: to negative outputs of source
- GND must be connected to source ground
- Wiring when driving using single ended source (TTL, CMOS or open collector)
- Positive (+) inputs: to positive outputs of source
- Negative (-) inputs: leave floating
- GND must be connected to source ground