Difference between revisions of "Argon specifications"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
(General)
(Regenerative resistor)
Line 46: Line 46:
 
===Motor output===
 
===Motor output===
 
===Regenerative resistor===
 
===Regenerative resistor===
 +
{| class="wikitable"
 +
|-
 +
! Property !! Value !! Units
 +
|-
 +
| Maximum current || 6 || A
 +
|-
 +
| Series fuse || 8A fast blow ||
 +
|-
 +
| Minimum resistance @ 230 VAC supply|| 70  || Ω
 +
|-
 +
| Minimum resistance @ 115 VAC supply|| 35  || Ω
 +
|-
 +
| Resistor power dissipation || 0-2400¹ || W
 +
|}
 +
¹) Power dissipation depends on how much system's kinetic energy is directed to the resistor
 +
 
===Feedback devices===
 
===Feedback devices===
 
===Inputs / outputs===
 
===Inputs / outputs===
 
===Communication===
 
===Communication===

Revision as of 11:41, 16 June 2013

This page lists official electrical and physical specifications of the Argon (servo drive).

Physical

Property Value Units
Dimensions (with wall mounting tabs)¹ TBD mm
Dimensions (excluding wall mounting tabs)¹ TBD mm
Weight TBD kg
Case materials Steel (cover), aluminum (heat sink)

¹) Wall mounting tabs are fixed part of enclosure

Electrical

General

Property Value Units
Operating temperature 10-70 °C
Storage temperature -30-90 °C
Humidity 0-95 non-condensing  %
Power dissipation 2-100¹ W

¹) Power dissipation is output current and input voltage related.

Power supply

Supply Input voltage Input current typ Input current max
Logic power 24 VDC +/- 10% 0.1 - 0.4 A 0.5 A
Motor power 85 - 264 VAC 50/60 Hz 0 - 15 A¹ 26 A¹
84 - 380 VDC 0 - 15 A¹ 26 A¹

¹) Estimating true current or power consumption based on this table may be difficult as current demand typically varies greatly and and almost completely depends on motor load conditions.

Motor output

Regenerative resistor

Property Value Units
Maximum current 6 A
Series fuse 8A fast blow
Minimum resistance @ 230 VAC supply 70 Ω
Minimum resistance @ 115 VAC supply 35 Ω
Resistor power dissipation 0-2400¹ W

¹) Power dissipation depends on how much system's kinetic energy is directed to the resistor

Feedback devices

Inputs / outputs

Communication