Difference between revisions of "Argon specifications"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
Line 16: Line 16:
 
|}
 
|}
 
¹) Wall mounting tabs are fixed part of enclosure
 
¹) Wall mounting tabs are fixed part of enclosure
==Electrical==
+
==Environment==
===General===
+
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 32: Line 31:
 
¹) Power dissipation is output current and input voltage related.
 
¹) Power dissipation is output current and input voltage related.
  
===Power supply===
+
==Power supply==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 44: Line 43:
 
|}
 
|}
 
¹) Estimating true current or power consumption based on this table may be difficult as current demand typically varies greatly and and almost completely depends on motor load conditions.
 
¹) Estimating true current or power consumption based on this table may be difficult as current demand typically varies greatly and and almost completely depends on motor load conditions.
===Motor output===
+
==Motor output==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 70: Line 69:
 
|}
 
|}
  
===Regenerative resistor===
+
==Regenerative resistor==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 87: Line 86:
 
¹) Power dissipation depends on how much system's kinetic energy is directed to the resistor
 
¹) Power dissipation depends on how much system's kinetic energy is directed to the resistor
  
===Feedback devices===
+
==Feedback devices==
====Status of feedback device support====
+
===Status of feedback device support===
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 110: Line 109:
 
|}
 
|}
 
¹) Supported already by hardware, usage possible after firmware upgrade
 
¹) Supported already by hardware, usage possible after firmware upgrade
====Quadrature encoder electrical properties====
+
===Quadrature encoder electrical properties===
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 122: Line 121:
 
|}
 
|}
  
===Inputs / outputs===
+
==Inputs / outputs==
 
For detailed specifications, see [[Argon user guide/J5 connector electrical interfacing|I/O electrical interfacing]].
 
For detailed specifications, see [[Argon user guide/J5 connector electrical interfacing|I/O electrical interfacing]].
 
{| class="wikitable"
 
{| class="wikitable"
Line 146: Line 145:
 
¹) Power dissipation is output current and input voltage related.
 
¹) Power dissipation is output current and input voltage related.
  
===Communication===
+
==Communication==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-

Revision as of 12:24, 16 June 2013

This page lists official electrical and physical specifications of the Argon (servo drive).

Physical

Property Value Units
Dimensions (with wall mounting tabs)¹ TBD mm
Dimensions (excluding wall mounting tabs)¹ TBD mm
Weight TBD kg
Case materials Steel (cover), aluminum (heat sink)

¹) Wall mounting tabs are fixed part of enclosure

Environment

Property Value Units
Operating temperature 10-70 °C
Storage temperature -30-90 °C
Humidity 0-95 non-condensing  %
Power dissipation 2-100¹ W

¹) Power dissipation is output current and input voltage related.

Power supply

Supply Input voltage Input current typ Input current max
Logic power 24 VDC +/- 10% 0.1 - 0.4 A 0.5 A
Motor power 85 - 264 VAC 50/60 Hz 0 - 15 A¹ 26 A¹
84 - 380 VDC 0 - 15 A¹ 26 A¹

¹) Estimating true current or power consumption based on this table may be difficult as current demand typically varies greatly and and almost completely depends on motor load conditions.

Motor output

Property Value Units Remarks
Continuous output current 0-10  A (peak value, not RMS) User settable limit
Peak output current 0-15 A (peak value, not RMS) Duration 1 sec, then returned to continuous limit. User settable current limit.
Switching frequency 17.5 kHz
Maximum modulation depth 88  % Maximum effective output is 88% of HV DC bus voltage.
Torque control bandwidth 1-3.3 kHz Motor dependent
Torque control cycle time 57.1 µs
Position & velocity control cycle time 400 µs
Power conversion efficiency 90-95  % Under typical conditions
Motor inductance range @ 230 VAC 1.4-25 mH
Motor inductance range @ 115 VAC 0.7-25 mH

Regenerative resistor

Property Value Units
Maximum current 6 A
Series fuse 8 A
Minimum resistance @ 230 VAC supply 70 Ω
Minimum resistance @ 115 VAC supply 35 Ω
Resistor power dissipation 0-2400¹ W

¹) Power dissipation depends on how much system's kinetic energy is directed to the resistor

Feedback devices

Status of feedback device support

Feedback device type Status
Quadrature incremental encoder (Differential:RS422) Included
Quadrature incremental encoder (Single ended: CMOS,TTL,open collector) Included
Hall sensors Included
Analog SinCos encoder Under development¹
Resolver/synchro Under development¹
Serial SSI encoder Planned¹
Serial BiSS encoder Planned¹
Tachogenerator Planned¹

¹) Supported already by hardware, usage possible after firmware upgrade

Quadrature encoder electrical properties

Property Value Units Remarks
Encoder count rate 0-4 MHz After 4x decoding, digitally filtered
Supply voltage 4.8-5.2 V Supplied from drive
Supply current 0-500 mA Supplied from drive

Inputs / outputs

For detailed specifications, see I/O electrical interfacing.

Property Value Units
Isolated digital input (GPIx) logic 1 voltage 3-24 V
Isolated digital input (GPIx) logic 0 voltage 0-1.3 V
Isolated digital output (GPOx) voltage 0-24 V
Isolated digital output (GPOx) current 50 mA
High speed digital input (HSINx) voltage range 2.7-5.5 V
Analog input input (ANAINx) voltage range ±10 V
Enable input input logic 1 voltage 20-25 V
STO input input logic 1 voltage 20-25 V

¹) Power dissipation is output current and input voltage related.

Communication

Property Value Units
Communication protocol SimpleMotion V2
Default bitrate 460800 BPS
Maximum number of Argon devices chained in a single bus 15 pcs
Command throughput Up to 10000 Commands/s