Tuning velocity controller

From Granite Devices Knowledge Wiki
Revision as of 13:51, 1 September 2013 by Tero K (Talk | contribs)


Jump to: navigation, search

Velocity controller tuning means finding the correct drive settings and feedback gain values to achieve a proper Servo stiffness and response to a velocity setpoint change.

This tuning guide is for you if the final application uses the motor in velocity control mode such as spindle or as position mode with external closed loop position controller such as LinuxCNC.

Velocity control tuning method

Preparations

An example of Testing tab settings for velocity controller tuning. Different settings should be experimented during the process to observe the stability and behavior of the settings.
Initial settings on Goals tab before beginning the example in this tuning guide.

Steps to do to begin position tuning:

  • Ensure that motor is parameterized correctly and working and torque control tuning has been properly done.
  • Attach motor to the target load and ensure it can rotate in both directions infinitely
  • Make following parameter changes to Granity and click apply afterwards:
    • Set drive in velocity control mode CM
    • Choose Serial only setpoint input CM
    • Make other necessary adjustments to have drive powered and enabled
    • Untick Setpoint smoothing CIS
    • Set Goals tab DIV and MUL to 50
    • Set acceleration CAL & velocity CVL limits reasonably to the levels that motor is expected to handle
  • Set-up the test stimulus and capture settings from Testing tab (an example, may be varied):
    • Set target setpoint 1 TSP1 between 1000 and 16383 (16383 equals the max speed that is configured via CVL)
    • Set delay 1 TSD1 to 0.25 seconds
    • Set target setpoint 2 TSP2 to same, but negative, value of TSP1
    • Set delay1 STD2 to 0.25 s
    • Choose sample rate TSR of 500 to 2500 Hz
    • Choose Capture setpoint change in positive direction from the dropdown
    • Tick Continuously repeating capture
    • Tick Velocity setpoint and Velocity achieved from signals
    • Tick Start capture to begin continous capture.
    • Tick Enable test stimulus TSE to begin a continuous position back and forth spinning motion generation

Once the steps above are done, motor should be generating direction reversing spinning and velocity response graphs should appear on the right side of Granity about once in 3-5 seconds.

Finding velocity control gain values

Tuning protocol

Tuning is begun with low or medium target speeds (TSP1 & 2 values below 5000).

Veltuning2.png

Initial velocity response with the default settings. As seen from the achieved velocity graph, it follows the setpoint velocity lazily and exhibits overshooting. In such state motor servo stiffness is low can be easily decelerated by adding load to the shaft.

Veltuning4.png

Begin tuning by increasing KVP gain. This makes motor follow velocty setpoint much better.

To try different gains, go to Tuning tab, change value and click the Apply settings button.


Veltuning3.png

When KVP has been increased too much, the system becomes unstable and may start oscillating. In such case, you may hit Esc button to disable drive, reduce the gain and enable drive again.

Tip: torque bandwidth has significant effect on the behavior of KVP value and the point where it goes unstable. One may experiment different TBW settings to find the optimum.

Veltuning6.png

Once a maximum perfectly stable KVP value has been found, start increasing KVI gain by a similar fashion. The higher KVI value is, the better servo stiffness.

Veltuning5.png

If KVP is increased too much, the result is overshooting and even sustained oscillation. The cure is similar to the too high KVP gain as described earlier.

Velocitylowgain.png

Once stable and stiff gains has been found, increase setpoint values (TSP1 & 2) to test the settings with higher speeds. If necessary adjust the gains experimentally to find the optimum tuning that works satisfactory on all needed speeds.

Advanced tuning: Feed-forwards

Feed-forward parameters may be used to boost motor responsiveness to setpoint change. Feed-forward gains VFF and AFF essentially compensate system friction and mass limiting the dynamic performance.

The recommended way to tune FF gains, is to start increasing velocity feed-forward VFF until the optimum level has been found. After that, increase acceleration feed-forward AFF until the optimum point has been reached.

Velocitylowgainff.png

In the image above a sharp response has been achieved even with low feedback gains as feed-forward gains help motor to accelerate as demanded.

Velocitystable.png

The image above shows similar response without feed-forwards but using high feedback gain values (optimally tuned according to the previous chapter).

Problem cases

In this test we run motor with higher speeds (TSPn > 10000) and illustrate few typical problem cases.

Currentsaturatin.png

The image above shows acceleration limited by insufficient torque produced by the motor. In this example the acceleration limit is set too high to be accelerated with the given motor torque limits (or current limits).

To verify if the problem happens due to torque limit, tick also Torque achieved and Torque setpoint signals from the Testing tab settings. In such way also motor currents will be displayed simultaneously with the position response curves. If the torque curve is limited to the set peak current limit MMC, then the problem is insufficient torque. In the image above we can see that the torque curves are saturated/clipping at 5A and -5A levels which matches the configured MMC value of 5A in this demonstration.

To help this, try:

  • Increasing current limits MMC and MCC if possible
  • Reducing acceleration CAL and/or velocity CVL limits

Velocityunstable.png

The above example shows instability and oscillation with high speeds even when the system was stable at lower speeds with the same parameters. In such case tune the system again at the most infavourable conditions and speeds to achieve stability over all required operating conditions.

Steps to do after tuning finished

  • Stop test stimulus by unticking TSE
  • Stop scope catpure by unticking Continuously repeating capture
  • Undo all temporary changes made to settings
  • Save settings to drive memory by clicking Save settings on drive non-volatile memory button
  • Set preferred setpoint source CRI, also consider the use of CIS
  • If setpoint signal scaling is needed, adjust MUL and DIV values

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.