Resolution of motors
Resolution and accuracy of position control motors depend on several factors.
Contents
Servo motor
Resolution
Servo motor resolution is determined by feedback device of motor. I.e. 1000 PPR (pulses per revolution) quadrature encoder yields 1/4000 revolutions because 1000 PPR equals 4000 counts per revolution after standard 4X decoding.
Accuracy
In most cases accuracy is more important value than resolution. Accuracy is more difficult to measure because it largely depends on mechanical load characteristics and dynamics. In ideal conditions the accuracy is very close to resolution but in most of practical cases the accuracy is 5 to 10 times less than resolution. I.e. 1000 PPR encoder can be expected to provide 1/400 to 1/800 revolutions accuracy.
Stepping motor
Resolution
Stepper resolution depends on number of magnetic steps per revolution and drive's electrical step angle size. Most modern drives implement microstepping to increase resolution and motion smoothness. Most common stepper resolution is 200 full steps per revolution but when driven for example with 16-microstep drive, the resulting resolution is 1600 steps per revolution (1/1600 revolutions).
Accuracy
Because steppers don't usually have feedback devices, the accuracy depends on motor load torque and motor linearity. Most stepping motor manufacturers quote angular accuracy of ±0.9° or 1/400 revolutions.
See also
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.