Goals tab

The Goals tab in the Granity serves following purpses:

Parameters

Drive function

Short GUI name GUI name Description How to use
CM Control mode Select drive operating control mode Select Torque, Velocity or Position mode. This setting affects the meaning of setpoint signal.

Setpoing input signal

Short GUI name GUI name Description How to use
CRI Setpoint input Source the of setpoint signal Choose one from Serial only SMV2, Pulse and direction, Quadrature, PWM or Analog setpoint
CIS Setpoint smoothing Low pass filtering of setpoint signal Tick the checkbox to smoothen the setpoint signal. This is useful if setpoint is noisy or jittering. However, if fastest response to the input is desired, leave this unticked. Also if using CAS>100%, this may help to smoothen the motion.
CAS Setpoint scaling factor Variable to adjust the scale of setpoint signal Value of 100% will pass the setpoint unchanged through the setpoint scaler. For example setting 200% here will equal doubling the amplitude of setpoint signal (i.e. in pulse train mode, one pulse equals two pulses, or in analog mode 5V equals 10V).

Motion dynamics - a.k.a. velocity & acceleration limits

Short GUI name GUI name Description How to use
CAL Acceleration limit Set maximum allowed acceleration rate, effective in position & velocity modes only The value is set as hardware units. Adjust the value and observe the right side value displaying the hardware value converted to a real world units such as revolutions/s. Make sure Machine tab settings are set-up first to get correct conversion.
CVL Velocity limit Set maximum allowed velocity, effective in position & velocity modes only
CSD Stop deceleration NO EFFECT CURRENTLY
CRV Error recovery velocity Set maximum allowed velocity of when drive is recovering from an error state and moves back to the setpoint. Effective in position mode only. If value set to 0, then no recovery motion will follow after reset errors.

Homing settings

Short GUI name GUI name Description How to use
HME Homing enabled
HMS Home switch polarity
HMI Index pulse search
HMH Hard stop detection threshold
HMT Motor current limit during homing
HMV Homing velicty limit
HMA Homing acceleration limit
HMF Offset home after homing
HFO Full speed offset move
HLL Position soft low limit
HHL Position soft high limit

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.