Replacing Argon fuse
Replacing Argon fuse may be necessary if it has blown or the application demands higher power than the default size fuse can handle. Accessing the fuse may be done by opening the cover by removing four screws at the bottom of the drive heat sink and carefully pulling the cover off.
Fuse location inside Argon circled in the picture above
The factory default fuse is 20x5 mm glass tube fuse T6.3A (time delay 6.3 A). This fuse can approximately support peak output power of 600W at 220-240 VAC supply.
The maximum allowed fuse size is time delayed 16A which supports over 1kW power. Please notice that installing larger than 6.3A fuse will exceed the rating of safe torque off STO1 relay capacity, thus relying on STO1 operation will no longer be fully safe. STO1 is safe only if input AC current is at most 6A RMS.
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.