Signal path of motor drive

From Granite Devices Knowledge Wiki
Revision as of 12:50, 7 April 2014 by Tero K (Talk | contribs)


Jump to: navigation, search

In Granite Devices drives the torque, velocity and position limits and setpoints are defined as integer numbers. The vales are represented "hardware" scale which are described below.

Setpoint signal path

Setpoint signal path converts user setpoint to internal setpoint.

Setpoint signal path

Main parts are:

  • Input multiplier. Purpose of this is to increase resolution of input setpoint to allow more fine grained velocity & acceleration control in trajectory planner. By default MUL value is 50.
  • Setpoint smoothing filter. If enabled, applies low pass filter to signal reducing jitter and roughness of signal but also introduces about some delay. By default the filter has 100% attenuation at 250Hz.
  • Trajectory planner. This limits rate of change of setpoint signal based on CVL and CAL parameters. Output rate maximum rate of change:
    • Velocity changes max CAL nubmer of units per control cycle (control cycle is 400µs in most GD drives)
    • Velocity maximum value is limited to CVL
  • Input divider. This divides setpoint signal by DIV to give desired output scale for internal setpoint. Combination of multiplier and divider can be used change total scaling of setpoint signal.

Internal setpoint

Internal setpoint equals the scale of feedback signals in position and velocity modes. The scale of feedback signals are:

  • Position feedback: position sensor counter raw value
  • Velocity feedback: number of feedback device counts per one control cycle. Obtained by calculating the difference of position feedback values at every control cycle.
  • Torque: hardware specific scale, however Torque scaler knows the hardware scale and scales internal setpoint so that value of +/-16384 represents full torque scale (i.e. internal setpoint value 16384 outputs configured peak current MMC and 8192 outputs MMC/2)


Driveblockdiagram setpoint v1.png

Controller

The default controller type of GD drives is cascaded type where each controlled variable has it's own PI or P controller. In position mode such structure is called as PIV controller.


Driveblockdiagram controller.png


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.