Argon user guide/J1 connector wiring
This page lists most common wiring schemes to Argon feedback device ports. For connector pin-outs, see the main article Argon user guide/Wiring.
Incremental encoder
Differential
Differential outputs (RS422 electrical standard) of encoder provides a good EMI immunity and supports long cables with high speed signals. Typical differential encoder has 6-8 wires:
- Ground
- Supply
- Channel A+
- Channel A-
- Channel B+
- Channel B-
- Index+ channel (optional)
- Index- channel (optional)
The negative outputs have the inverted (or mirror image) signal of the positive outputs.
J1 pin # | Pin name | Pin function | Encoder wire |
---|---|---|---|
Shell | PE | Earth/case | Cable shield |
5 | CHB- | Differential input B- | Channel B- |
6 | CHB+ | Differential input B+ | Channel B+ |
7 | CHA- | Differential input A- | Channel A- |
8 | CHA+ | Differential input A+ | Channel A+ |
9 | 5V_OUT | Encoder supply 5V output | Encoder supply |
10 | GND | Encoder supply ground | Encoder ground |
14 | CHC- | Differential input C- | Index- channel |
15 | CHC+ | Differential input C+ | Index- channel |
Pins not listed in the table are left open or used for other functions such as Hall sensor.
Single ended
Single ended output type is usually one of the following:
- Open collector outputs
- TTL outputs
- CMOS outputs
Typical single ended encoder has 4-5 wires:
- Ground
- Supply
- Channel A
- Channel B
- Index channel (optional)
J1 pin # | Pin name | Pin function | Encoder wire |
---|---|---|---|
Shell | PE | Earth/case | Cable shield |
6 | CHB+ | Differential input B+ | Channel B |
8 | CHA+ | Differential input A+ | Channel A |
9 | 5V_OUT | Encoder supply 5V output | Encoder supply |
10 | GND | Encoder supply ground | Encoder ground |
15 | CHC+ | Differential input C+ | Index channel |
Pins not listed in the table are left open or used for other functions such as Hall sensor.
Hall sensor
Some AC/BLDC/Linear motors are equipped with a Hall sensor which allows faster drive initialization after power-on. Hall sensor is also necessary in the case where motor is not able to move freely in both directions when powered on (i.e. if axis rests at the end of mechanical travel or is vertical axis).
Many Hall sensors have differential outputs (non-inverted and inverted channels, just like differential encoder), however Argon has only single ended Hall sensor inputs which supports both output types (single ended and differential).
It is possible to connect a Hall sensor together with other feedback devices to the same port. In such case supply pins may be shared between multiple FBD's.
J1 pin # | Pin name | Electrical function | Hall sensor wiring |
---|---|---|---|
Shell | PE | Earth/case | Feedback cable shield |
1 | HALL_W | Hall sensor input, phase W | Hall sensor W (if differential, then W+ channel) |
2 | HALL_V | Hall sensor input, phase V | Hall sensor V (if differential, then V+ channel) |
3 | HALL_U | Hall sensor input, phase U | Hall sensor U (if differential, then U+ channel) |
9 | 5V_OUT | Encoder supply 5V output | Hall sensor supply |
10 | GND | Encoder supply ground | Hall sensor ground |
Pins not listed in the table are left open or used for other functions such as Hall sensor.
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.