Fault limits tab

From Granite Devices Knowledge Wiki
Jump to: navigation, search

This tab serves as:

  • Set fault triggering levels and tolerances

Parameters

Drive fault limits

Short GUI name GUI name Description How to use
FOC Over current tolerance Set sensitivity of over current faults This variable defines how much over current (measured motor phase current above the peak current limit (Machine/MMC) drive allows before entering into fault state. The Minimum setting has lowest threshold and gives fault easier, Maximum tolerates largest over current spikes before faulting.

Set this as low as possible without getting OC faults in normal use to maximally protect your equipment. If larger than Medium setting is needed, see Over current fault troubleshooting for solution to the problem.

FOV Over voltage fault threshold Maximum allowed HV DC bus voltage before entering into over voltage fault. Also defines at which voltage drive starts driving braking resistor to reduce bus voltage. If supplying drive from 220-240 VAC mains, set this 340-360 VDC. If supplying 110-120 VAC, set this to 170-200 VDC.
FUV Under voltage fault threshold Minimum allowed HV DC bus voltage before drive starts motor initialization after power-on. Also if this voltage is exceeded during active operation, drive enters into under voltage fault state. If supplying drive from 220-240 VAC mains, set this 200 VDC. If supplying 110-120 VAC, set this to 100 VDC.

Goal deviation faults

These settings define how much motor may deviate from the setpoints before entering in fault state.

Short GUI name GUI name Description How to use

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.