Testing tab
This tab serves following purposes:
- Running repeating test sequence on motor
- Capturing reference signal & feedback graphs from drive
Test stimulus generator
Test stimulus generator is a way to feed a repeating setpoint signal to the drive without having any other physical signals supplied. Test stimulus generates a square waveform with user specified amplitudes and timing.
The waveform generated is specified by 4 parameters:
Short GUI name | GUI name | Description | How to use |
---|---|---|---|
TSP1 | Target setpoint 1 | The first setpoint level | Adjust the value and observe the right side value conversion to the real world units such as amperes or millimeters. |
TSD1 | Delay 1 | The active duration of the first setpoint | Set the duration of the first setpoint lenght. |
TSP2 | Target setpoint 2 | The second setpoint level | Adjust the value and observe the right side value conversion to the real world units such as amperes or millimeters. |
TSD2 | Delay 2 | The active duration of the second setpoint | Set the duration of the second setpoint length. |
TSE | Enable test stimulues | Control test stimulus feed | Tick this checkbox to instantly start feeding test stimulus to the drive. Before ticking ensure that setpoints are set to safe levels and always be prepared stop motor safely if unexpected motion happens. |
Example where TSD1=0.1s TSD2=0.5s TSP1=1000→0.18A TSP2=-500→-0.09A |
Set Abs and Set Inc buttons
Set Abs button set the TSP1 or TSP2 value immediately as setpoint.
Set Inc button does the same as Set Abs, but instead of setting absolute value, setpoint is being incremented. I.e. if TSP1=100 and click 5 times Set Inc, then setpoint value becomes 500.
Capture & graphs
Capture controls
Options are:
- [TSR] Sample rate - choose the sampling rate of the signals. The higher sampling rate used, the higher level detail will be captured (good to observe sharply changing edges of signal) but at the same time lenght of recorded capture will be shorter. Lower sample rate loses some detail, but gives longer capture duration.
- Capture trigger dropbox - choose one of the following:
- Capture instantly - Start capture button starts capture immediately
- Capture in fault - Start capture button waits until drive faults and begins capture at the moment of fault occurring
- Capture on setpoint change - Start capture button waits until setpoint is modified
- Capture on setpoint change in positive direction - Start capture button waits until setpoint is modified in positive direction (capture not occurring if setpoint value is reduced)
- Continuously repeating capture - if ticked, capture will be repeating continuously. Useful with test stimulus generator.
Capture signals selection
Tick the checkboxes to choose which signals to capture and display on the graph. The more signals selected, the less the capture duration will be. I.e. if one chooses 4 signals instead of 2, the time of capture will reduce to 1/2.
Device state
Devices state updates continuously while connected and shows status & fault register bits as well as state of physical I/O lines and setpoint value.
Status
Name | Description | Troubleshooting |
---|---|---|
Initialized | True when drive has completed initialization procedure (such as phasing) | If never goes on, check parameters, drive input voltage, safe torque off and enable inputs and possible faults. |
Error recovering | True when drive performs position return to the setpoint position after clear faults command is given | |
Tracking error warn | True when position or velocity tracking error is greater than 1/8 of fault limit (FPT or FVT) | |
Target reached | True when drive's internal motion profiler (velocity & acceleration limited motion) has reached the user setpoint value | |
Enabled | True when drive has enabled state on. This allows drive to control motor if no faults are active. | |
Run | True when drive is initializing or controlling motor. Goes false if enabled is false or faults are active | |
Homing active | True when drive is performing homing sequence. Goes false after homing is complete or not enabled | |
Braking | True when motor is being braked electrically and/or mechanically | |
Permanent stop | True when drive requires restart before continuing motor control. Goes true when changing certain parameters or if initialization fails | Restart drive to see if the state clears. If not, check parameterization and usage errors. |
Voltages good | True when HV DC bus voltage is withing configured range (from FUV to FOV) | |
Fault stopped | True when drive is disabled true to active fault state | Perform clear drive faults function (from Connect tab). If problem repeats, check motor & tuning parameters and operating conditions. See fault register and fault location for hints. |
Ready for use | True when drive has performed all initializations, possible homing and is enabled and running. When true, drive is ready to follow user setpoint commands | |
STO active | True when safe torque off is active. In Argon this monitors only STO2. |
Fault register
Name | Description | Troubleshooting |
---|---|---|
Tracking error | Drive stopped due to position or velocity tracking error getting larger than configured limit (FPT or FVT) | Check settings, operating conditions and fault limits to resolve. |
Over velocity | Motor has exceeded the speed limit defined at FEV | |
Hardware | Drive internal error has occurred | Possibly external interference (check wiring and EMI suppression) and stability of logic supply voltage. If problem stays, contact Granite Devices support. |
Over temperature | Drive temperature has exceeded its maximum value | |
Feedback | Failure in feedback device has been detected | |
Over current | Measured current was exceeding the limit value (current spike) | Check wiring or try different FOC value |
Internal comm error | Drive internal error has occurred | Possibly external interference (check wiring and EMI suppression) and stability of logic supply voltage. If problem stays, contact Granite Devices support. |
Power stage forced off | True when some of the fault states is forcing power stage off to protect drive. Motor is freely spinning unless braked mechanically. | |
Under voltage | HV DC bus voltage below FUV value | Check voltage, parameters and safe torque off |
Over voltage | HV DC bus voltage above FOV value | Check voltage and FOV. If happens during motor deceleration, then a braking resistor is needed. |
Motion range | Motor has been commanded outside the allowed travel boundary. I.e. driven to limit switch when LFS is set to fault stop | |
Firmware error | Drive internal error has occurred | Possibly external interference (check wiring and EMI suppression) and stability of logic supply voltage. If problem stays, contact Granite Devices support. |
Init | Initialization failed. Possible reasons: drive disabled or faulted during initialization or initialization time-outed | Check enable signal, parameters, wiring and faults |
Motion | Motor stall or loss of feedback signal detected | Adjust FMO to larger value or disable it |
SimpleMotion | SimpleMotion V2 Communication error detected, possibly connection lost, invalid parameter value is sent or transfer error caused by EMI or bad wiring | |
Fault location ID | See Fault location |
Troubleshooting
- Fault location helps to identify the source of faults if nonzero
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.