Template:IONI setpoint signals

From Granite Devices Knowledge Wiki
Revision as of 20:09, 28 August 2015 by Tero K (Talk | contribs) (Text replacement - "\[\[([A-Z]{2,3})]]" to "{{param|$1}}")


Jump to: navigation, search

Setpoint mode is selected by software with parameter Setpoint inputCRI and behavior is affected by parameters Setpoint smoothingCIS, Setpoint multiplierMUL, Setpoint dividerDIV, Setpoint offset nullingCAO and Enable direction inputCED.

Signal name Function Used for Remarks
HSIN1 High speed digital input 1 Depending on setpoint mode, can be either:
HSIN2 High speed digital input 2 Depending on setpoint mode, can be either:
  • Direction signal of pulse train (in Pulse and direction setpoint mode)
  • Quadrature B channel (in quadrature setpoint mode)
  • PWM (in PWM and PWM+Dir setpoint modes)
ANAIN- Differential analog negative input Used for analog setpoint mode Setpoint voltage is the voltage difference between ANAIN+ and ANAIN-
ANAIN+ Differential analog positive input Used for analog setpoint mode