Template:DriveFaultbits
From Granite Devices Knowledge Wiki
Revision as of 14:21, 16 June 2017 by Tero K (Talk | contribs) (Created page with "{| class="wikitable" |- ! Name !! Description !! Troubleshooting !! Filter time before activation |- |Tracking error || Drive stopped due to position or velocity tracking erro...")
Name | Description | Troubleshooting | Filter time before activation |
---|---|---|---|
Tracking error | Drive stopped due to position or velocity tracking error getting larger than configured limit (Position tracking error thresholdFPT or Velocity tracking error thresholdFVT) | Check settings, operating conditions and fault limits to resolve. | Goal faults filter timeFFT |
Over velocity | Motor has exceeded the speed limit defined at Over speed faultFEV | Goal faults filter timeFFT | |
Hardware | Drive internal error has occurred | Possibly external interference (check wiring and EMI suppression) and stability of logic supply voltage. If problem stays, contact Granite Devices support. | None |
Over temperature | Drive temperature has exceeded its maximum value | None | |
Feedback | Failure in feedback device has been detected | None | |
Over current | Measured current was exceeding the limit value (current spike) | Check wiring or try different Over current toleranceFOC value | Affected by Over current toleranceFOC |
Internal comm error | Drive internal error has occurred | Possibly external interference (check wiring and EMI suppression) and stability of logic supply voltage. If problem stays, contact Granite Devices support. | None |
Power stage forced off | True when some of the fault states is forcing power stage off to protect drive. Motor is freely spinning unless braked mechanically. | None | |
Under voltage | HV DC bus voltage below Under voltage fault thresholdFUV value | Check voltage, parameters and safe torque off | None |
Over voltage | HV DC bus voltage above Over voltage fault thresholdFOV value | Check voltage and Over voltage fault thresholdFOV. If happens during motor deceleration, then a braking resistor is needed. | None |
Motion range | Motor has been commanded outside the allowed travel boundary. I.e. driven to limit switch when Limit switch functionLFS is set to fault stop | None | |
Firmware error | Drive internal error has occurred | Possibly external interference (check wiring and EMI suppression) and stability of logic supply voltage. If problem stays, contact Granite Devices support. | None |
Init | Initialization failed. Possible reasons: drive disabled or faulted during initialization or initialization time-outed | Check enable signal, parameters, wiring and faults | None |
Motion | Motor stall or loss of feedback signal detected | Adjust Motion fault thresholdFMO to larger value or disable | Goal faults filter timeFFT |
SimpleMotion | SimpleMotion V2 Communication error detected, possibly connection lost, invalid parameter value is sent or transfer error caused by EMI or bad wiring | None | |
Fault location ID | See Fault location |