Argon user guide/Power supply safe discharging
Power supplies and drives have capacitors that store electricity even when power supply has been disconnected from the power network. This poses electric shock hazard when touching a device that has been just unplugged from the power line.
Safely discharging Argon drive
Argon (servo drive) has internal power supply bleeding resistor that will discharge the capacitors during 5 minutes after AC power has been removed.
To safely touch Argon:
- Remove AC power (both L and N lines). This can be done for example by unplugging the power cord from wall socket where the power comes from.
- Wait 5 minutes after removing AC to allow capacitor voltage discharge.
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.