Dead-time distortion

From Granite Devices Knowledge Wiki
Jump to: navigation, search

Dead time distortion (DTD) is a type of cross-over distortion caused by dead-time state of PWM power stages. The problem is present in all PWM output drives. The longer dead time used, the more significant distortion becomes.

About dead-time

Dead-time is a blanking time period (upper & lower transistors in off-state simultaneously) of half-bridge power stage. Both transistors are switched off for short period of time to prevent both transistors conducting simultaneously thus causing a short circuit from supply to ground.

Distortion phenomenon

Dead time distortion explanation

Dead time distortion is present in some extent in all half-bridge topology PWM power outputs.

Description of the image:

  1. Schematic: typical single phase half-bridge PWM power output consisting two transistors and an inductive load (inductor). In 3 phase motor drives there are 3 pcs of this kind of circuits excluding inductor (which is replaced by a motor coil).
  2. Desired load voltage waveform: the distortion free waveform reference signal on load that we would want to see.
  3. PWM to top transistor: PWM signal that is controls when the top side transistor is in conductive state.
  4. PWM to bottom transistor: PWM signal that is controls when the bottom side transistor is in conductive state.
  5. Grey areas: dead-time when neither of transistors are in conducting state and during this time current will free-wheel thru diodes. Dead-time is necessary to prevent on-state overlapping and shoot-through currents from V+ to GND.
  6. Positive current load voltage: this is the achieved (distorted) PWM signal on load when current direction is positive in load inductor.
  7. Negative current load voltage: this is the achieved (distorted) PWM signal on load when current direction is negative in load inductor.

As it figure shows, actual output voltage differs from desired load voltage. Actual PWM duty cycle either becomes higher or lower than desired and distortion direction changes whenever current direction reverses.

Distortion effects

Measured torque ripple as function of time when motor is rotating. Torque reference was constant so in ideal case this curve would be flat but instead it shows significant drops in torque periodically. No DTD distortion correction was used.

Some of most notable motion control problems caused by DTD:

  • Unwanted ripple in torque that may reduce motion smoothness
  • Causes "electrical backlash" or laziness on motor control. With DTD, motor reaction time is increased whenever current direction is reversed (such as motor is reversing direction). This increases tracking error of servo motor.
  • More difficulty in servo tuning
  • Reduced servo stiffness

DTD does not limit to motion control. For example it also affects class D audio amplifiers. [1]

Measurements

Dead time distortion

Distortion correction disabled. Top graph: phase current reference and achieved current. Bottom graph: PWM duty cycle reference

These graphs show actual distortion on sinusoidal motor currents when PWM frequency was 17.5 kHz and dead-time length 2 µs. No countermeasures were taken to reduce distortion.

Notice the current dips in otherwise sinusoidal signal. There are 6 dips per sine cycle because in this experiment the test was done on a 3 phase motor which has 3 sine currents with 60 degree phase angle differences. Only one phase is displayed but distortion of two remaining phases will induce dips also in the neighbor phases.

Also notice how PWM duty cycle reference from drive torque/current controller jumps up/down trying to compensate dead time errors. However, no current controller alone is fast enough to completely eliminate current ripples.

Distortion elimination

VSD-XR distortion correction enabled. Top graph: phase current reference and achieved current. Bottom graph: PWM duty cycle reference

The bottom image shows the exactly same experiment with the one above but this time VSD-XR dead time correction was turned on. Notice how dips almost completely disappear and PWM duty cycle reference shows more sine-like waveform.


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.