This page supports semantic in-text annotations (e.g. "[[Is specified as::World Heritage Site]]") to build structured and queryable content provided by Semantic MediaWiki. For a comprehensive description on how to use annotations or the #ask parser function, please have a look at the getting started, in-text annotation, or inline queries help page.

Latest revision Your text
Line 8: Line 8:
 
Inrush current limiter is based on a resistor which is bypassed by a [[GraniteCore]] controlled relay after HV DC supply has risen near nominal levels.
 
Inrush current limiter is based on a resistor which is bypassed by a [[GraniteCore]] controlled relay after HV DC supply has risen near nominal levels.
  
Verifying internal [[HV DC bus]] voltage can be done by reading the voltage value from Granity Testing tab '''or''' by measuring DC voltage between VP and VN terminals. The voltage between VP and VN is directly connected to the power stage, so if there is voltage between these terminals, then drive's HV supply is properly powered and it is possible to drive motor.
+
Verifying internal [[HV DC bus]] voltage can be done by reading the voltage value from Granity Testing tab or by measuring DC voltage between VP and VN terminals.
 
+
 
==Checking for AC to HV DC signal path components==
 
==Checking for AC to HV DC signal path components==
 
{{Electricshock|Before proceeding with the tests, make sure drive has been safely discharged for at least 15 minutes before opening it. Any remaining voltage in the device may interfere the measurements here. See more info [[Power supply safe discharging|here]].}}
 
{{Electricshock|Before proceeding with the tests, make sure drive has been safely discharged for at least 15 minutes before opening it. Any remaining voltage in the device may interfere the measurements here. See more info [[Power supply safe discharging|here]].}}
Line 34: Line 33:
 
Measuring condition of B3 is possible with multimeter's diode check function. Check all four diodes from the test points marked in the image. Multimeter red lead goes to anode and black to cathode. All diodes should give reading of 0.4 to 0.5 Volts.
 
Measuring condition of B3 is possible with multimeter's diode check function. Check all four diodes from the test points marked in the image. Multimeter red lead goes to anode and black to cathode. All diodes should give reading of 0.4 to 0.5 Volts.
 
[[File:Argondiodebridge.jpg|thumb|Diode bridge B3 measurement points circled]]
 
[[File:Argondiodebridge.jpg|thumb|Diode bridge B3 measurement points circled]]
 
[[Category:Argon]]
 
[[Category:Argon_troubleshooting]]
 

Please note that all contributions to Granite Devices Knowledge Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Granite Devices Knowledge Wiki:Copyrights for details). Do not submit copyrighted work without permission!

Select categories:

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)