{{ArgonManualNav}} | {{ArgonManualNav}} | ||
− | ==Mechanical installation | + | ==Mechanical installation== |
− | [[File:Argon installation.png|thumb|A proper Argon installation orientation and spacing with optional [[Argon user guide/Mating connectors and accessories|heat sinks]] and | + | [[File:Argon installation.png|thumb|A proper Argon installation orientation and spacing with optional [[Argon user guide/Mating connectors and accessories|heat sinks]] and a cooling fan.]]Argon drives should be installed vertically (J5 connector up) with at least 50 mm free air space between the device surfaces and possible cabinet walls to allow heat transfer along the heat sink side of the device. |
− | Cooling may be further by mounting additional [[Argon user guide/Mating connectors and accessories|heat sinks]] to the bottom of the device and/or using a fan blowing air from bottom to up. | + | Cooling may be further by mounting additional [[Argon user guide/Mating connectors and accessories|heat sinks]] to the bottom of the device and/or using a fan blowing air from bottom to up. Such additional cooling measures are typically necessary only when average output current is higher than 4 Amperes. |
− | + | ||
− | Such additional cooling measures are typically necessary only when | + | |
+ | Most of [[Control modes|position control]] servo systems run cool enough without additional cooling as the load is highly varying and the average output power is low. | ||
==Wiring overview== | ==Wiring overview== | ||
[[File:Wiringoverview notitle.png|600px]] | [[File:Wiringoverview notitle.png|600px]] | ||
− | + | ||
− | + | ||
;The minimum wiring for a servo system (after configuration state): | ;The minimum wiring for a servo system (after configuration state): | ||
− | # Safety [[Argon user guide/Earthing|earthing ]]to port J4 | + | # Safety [[Argon user guide/Earthing|earthing ]]to port J4 and preferably to the Argon case |
# 24 VDC wiring to port J3 | # 24 VDC wiring to port J3 | ||
# [[Safe torque off]] and enable signals to port J2. See [[SimpleMotion V2 port|how]]. | # [[Safe torque off]] and enable signals to port J2. See [[SimpleMotion V2 port|how]]. | ||
Line 31: | Line 29: | ||
==Ports and connectors== | ==Ports and connectors== | ||
[[File:Argonfront.png|800px|Argon front side connections]] | [[File:Argonfront.png|800px|Argon front side connections]] | ||
− | |||
[[File:ArgonSideIO.png|550px|Argon side connections & DIP switches]] | [[File:ArgonSideIO.png|550px|Argon side connections & DIP switches]] | ||
Line 78: | Line 75: | ||
===Connecting multiple drives=== | ===Connecting multiple drives=== | ||
Note this drawing does not include wiring to motor (J4), motor brake (J3), feedback device (J1), controller (J5) and AC power input circuity. | Note this drawing does not include wiring to motor (J4), motor brake (J3), feedback device (J1), controller (J5) and AC power input circuity. | ||
− | |||
[[File:Argon_wiring_multiple.png|800px]] | [[File:Argon_wiring_multiple.png|800px]] | ||
− | |||
===Wiring of single drive=== | ===Wiring of single drive=== | ||
[[File:Argonwiringoverview.png|800px]] | [[File:Argonwiringoverview.png|800px]] | ||
− | |||
− |