{{ArgonManualNav}} | {{ArgonManualNav}} | ||
==Mechanical installation and cooling== | ==Mechanical installation and cooling== | ||
− | [[File:Argon installation.png|thumb|A proper Argon installation orientation and spacing with optional [[Argon user guide/Mating connectors and accessories|heat sinks]] and an optional cooling fan | + | [[File:Argon installation.png|thumb|A proper Argon installation orientation and spacing with optional [[Argon user guide/Mating connectors and accessories|heat sinks]] and an optional cooling fan.]]Argon drives should be installed vertically (J5 connector up) with at least 50 mm free air space between the device surfaces and possible cabinet walls to allow heat transfer along the heat sink side of the device. |
Cooling may be further by mounting additional [[Argon user guide/Mating connectors and accessories|heat sinks]] to the bottom of the device and/or using a fan blowing air from bottom to up. If fan is used, it should have dust filter to prevent dust inside the drives. | Cooling may be further by mounting additional [[Argon user guide/Mating connectors and accessories|heat sinks]] to the bottom of the device and/or using a fan blowing air from bottom to up. If fan is used, it should have dust filter to prevent dust inside the drives. | ||
Line 9: | Line 9: | ||
==Wiring overview== | ==Wiring overview== | ||
[[File:Wiringoverview notitle.png|600px]] | [[File:Wiringoverview notitle.png|600px]] | ||
− | + | ||
− | + | ||
;The minimum wiring for a servo system (after configuration state): | ;The minimum wiring for a servo system (after configuration state): | ||
− | # Safety [[Argon user guide/Earthing|earthing ]]to port J4 | + | # Safety [[Argon user guide/Earthing|earthing ]]to port J4 and preferably to the Argon case |
# 24 VDC wiring to port J3 | # 24 VDC wiring to port J3 | ||
# [[Safe torque off]] and enable signals to port J2. See [[SimpleMotion V2 port|how]]. | # [[Safe torque off]] and enable signals to port J2. See [[SimpleMotion V2 port|how]]. | ||
Line 31: | Line 30: | ||
==Ports and connectors== | ==Ports and connectors== | ||
[[File:Argonfront.png|800px|Argon front side connections]] | [[File:Argonfront.png|800px|Argon front side connections]] | ||
− | |||
[[File:ArgonSideIO.png|550px|Argon side connections & DIP switches]] | [[File:ArgonSideIO.png|550px|Argon side connections & DIP switches]] | ||
Line 78: | Line 76: | ||
===Connecting multiple drives=== | ===Connecting multiple drives=== | ||
Note this drawing does not include wiring to motor (J4), motor brake (J3), feedback device (J1), controller (J5) and AC power input circuity. | Note this drawing does not include wiring to motor (J4), motor brake (J3), feedback device (J1), controller (J5) and AC power input circuity. | ||
− | {{caution|Using HV DC bus sharing via VP and VN terminals or supplying external DC voltage to them, renders the [[safe torque off]] | + | {{caution|Using HV DC bus sharing via VP and VN terminals or supplying external DC voltage to them, renders the [[safe torque off]] STO1 input unusable. In order to preserve STO1 functionality with DC bus sharing, the STO1 signal must be fed simultaneously to all DC bus sharing drives. If an external DC supply is used (no AC input to L & N), then STO1 will not operate.}} |
[[File:Argon_wiring_multiple.png|800px]] | [[File:Argon_wiring_multiple.png|800px]] | ||
===Wiring of single drive=== | ===Wiring of single drive=== | ||
[[File:Argonwiringoverview.png|800px]] | [[File:Argonwiringoverview.png|800px]] | ||
− | |||
− |