Charge pump enable input
Charge pump enable input means an drive enable signal that needs to be toggled at certain frequency to make a valid enable command. Any static level for charge pump enable signal will be interpreted as disabled state. The purpose of charge pump function is to verify that the controller is connected and alive thus enhance the safety of system.
Enable input signal | Drive state with charge pump enable | Drive state without charge pump enable |
---|---|---|
Logic low | Disabled | Disabled |
Logic high | Disabled | Enabled |
Toggling low & high | Enabled | Invalid input |
Support[edit | edit source]
IONI drive supports charge pump enable and the function can be activated by setting checkbox CEP (Require pulsing on enable input) on. IONI will accept toggling frequency between 200 to 15000 Hz.
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.